Evidence map›Paper›PMID 33849652›Full record

ArticleBiomaterials research2021

Correlation between two-dimensional micro-CT and histomorphometry for assessment of the implant osseointegration in rabbit tibia model.

Hao-Zhen Lyu, Jae Hyup Lee

Open access · goldAbstract read
In one paragraph

Article in Biomaterials research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Hao-Zhen LyuDepartment of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Boramae-ro 5-gil 20, Dongjak-gu, Seoul, 07061, South Korea.ORCID https://orcid.org/0000-0001-9802-2723
Jae Hyup LeeDepartment of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Boramae-ro 5-gil 20, Dongjak-gu, Seoul, 07061, South Korea. spinelee@snu.ac.kr.ORCID http://orcid.org/0000-0002-2141-0266
Seoul National University · KR

Funding

Basic Science Research Program of the National Research Foundation of Korea (NRF) funded by the Ministry of Education 2013R1A1A2061858
6 · The paper itself

Abstract

backgroundHistology is considered as a gold standard for analyzing bone architecture. However, histomorphometry is a destructive method and only offers the bone information of a limited location. Micro-computed tomography (μCT) is a non-destructive technology and provides a slice at any site. The aim of this study was to compare the correlation of the Bone-to-Implant Contact ratio (BIC) between 2D micro-CT (μCT) and histomorphometry and to investigate a method for assessing the osseointegration of the implant by 2D μCT.

methodsA total of 18 implants were divided into three groups (6 implants per group), and inserted into the rabbit tibia defects as follow: implant only (Implant group), implant with β-TCP/hydrogel (TCP group), implant with rhBMP-2 loaded β-TCP/hydrogel composite (BMP-2 group). After 4 weeks of implantation, the specimens were collected to take the micro-CT scan with an aluminum filter and performed H&E staining on the undecalcified sections. The 2D μCT slices were chosen at an angle of 0°, 45°, 90° and 135° with the representative histological section to measure BIC. And the correlations between BICs of 2D μCT and BICs of histology were evaluated.

resultsIn each group, BICs at the same sites measured by histomorphometry and corresponding 2D μCT presented the same trend and shown no significant difference between the two methods (P > 0.05). BICs of histological sections and BICs of corresponding 2D μCT slices presented a strong correlation in the implant group (γ = 0.74, P = 0.09), a moderate correlation in the TCP group (γ = 0.46, P = 0.35), a weak correlation in the BMP-2 group (γ = 0.30, P = 0.56). In the implant group, the relationship between BIC-Mean-μCTs and BICs-Histology has presented a significant linear correlation (γ = 0.84, P = 0.04).

conclusionsIntegrating bone information of several 2D μCT slices in different sites to measure BIC is a feasible method for assessing the implant osseointegration.

Indexed as

Bone-implant interfaceHistologyOsseointegrationX-ray microtomography

Identifiers

PMID33849652
PMCPMC8042957
OpenAlexW3154186461

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.