Evidence map›Paper›PMID 33849489›Full record

ArticleBMC musculoskeletal disorders2021

The accelerometer-based navigation system demonstrated superior radiological outcomes in restoring mechanical alignment and component sagittal positioning in total knee arthroplasty.

Jiaxiang Gao, Yunfei Hou, Rujun Li, Yan Ke, Zhichang Li, Jianhao Lin

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jiaxiang Gao *Arthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, 100044, China.
Yunfei Hou *Arthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, 100044, China.
Rujun LiArthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, 100044, China.
Yan KeArthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, 100044, China.
Zhichang LiArthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, 100044, China. li_zhichang@pkuph.edu.cn.
Jianhao LinArthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, 100044, China. linjianhao@pkuph.edu.cn.
Peking University · CNPeking University People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to determine whether the accelerometer-based navigation (ABN) could improve the accuracy of restoring mechanical axis (MA), component positioning, and clinical outcomes compared to conventional (CON) total knee arthroplasty (TKA).

methodsA total of 301 consecutive patients (ABN: 27, CON: 274) were included. A 1:4 propensity score matching (PSM) was performed between the two groups according to preoperative demographic and clinical parameters. The postoperative MA, femoral coronal angle (FCA), femoral sagittal angle (FSA), tibial coronal angle (TCA) and tibial sagittal angle (TSA) were compared. Absolute deviations of aforementioned angles were calculated as the absolute value of difference between the exact and ideal value and defined as norms if within 3°, otherwise regarded as outliers. Additional clinical parameters, including the Knee Society knee and function scores (KSKS and KSFS) and range of motion (ROM), were assessed at final follow-up (FU) (mean FU was 21.88 and 21.56 months respectively for ABN and CON group). A secondary subgroup analysis and comparison on clinical outcomes were conducted between norms and outliers in different radiological parameters.

resultsA total of 98 patients/102 knees were analyzed after the PSM (ABN: 21 patients/24 knees, CON: 77 patients/78 knees). In the ABN group, the mean MA, FCA and TSA were significantly improved (p = 0.019, 0.006, < 0.001, respectively). Proportions of TKAs within a ± 3°deviation were significantly improved in all the postoperative radiological variables except for TCA (p = 0.003, 0.021, 0.042, 0.013, respectively for MA, FCA, FSA, and TSA). The absolute deviations of FSA and TSA were also significantly lower in the ABN group (p = 0.020, 0.048, respectively). No significant differences were found in either mean value, absolute deviation or outlier ratio of TCA between two groups. On clinical outcomes, there were no significant differences between two groups, although KSKS, KSFS and ROM (p < 0.01, respectively) dramatically improved compared to baseline. The subgroup analysis also demonstrated no statistical difference on clinical outcomes between the outliers and norms in varied radiological parameters.

conclusionsThe ABN could improve the accuracy and precision of mechanical alignment and component positioning without significant improvement of clinical outcomes. Further high quality studies with long term FU are warranted to comprehensively evaluate the value of the ABN.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeSurgery, Computer-AssistedAccelerometryHumansKnee JointTibiaAccelerometer-based navigationComponent sagittal positioningMechanical axisTotal knee arthroplasty

Identifiers

PMID33849489
PMCPMC8045229
OpenAlexW3112289514

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.