ArticleScientific reports2021
The mechanical characteristics and performance evaluation of a newly developed silicone airway stent (GINA stent).
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 20 citations in OpenAlex.
- Additive Manufacturing of Polymeric Bioresorbable Stents: A Mechanical Performance Perspective.Biomaterials research · 2026Review
- Paclitaxel-eluting silicone airway stent with sustained drug release and potent anti-fibrotic activity.Frontiers in bioengineering and biotechnology · 2026Article
- Airway Malacia: Stent Innovations and Emerging Ex Vivo Testing Platforms.Seminars in thoracic and cardiovascular surgery. Pediatric cardiac surgery annual · 2026Review
- Can Smart Alloy Material Improve the Biomechanical Behavior of Prostheses Used in the Human Trachea? A Fluid-Structure Interaction Approach.Biomedical engineering and computational biology · 2025Article
- Advances in studies on tracheal stent design addressing the related complications.Materials today. Bio · 2024Review
- [Numerical study on structural design and mechanical analysis of anti-migration tracheal stent with non-uniform Poisson's ratio].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024Article
- A novel ex vivo tracheobronchomalacia model for airway stent testing and in vivo model refinement.The Journal of thoracic and cardiovascular surgery · 2023Article
- A narrative review of progress in airway stents.Journal of thoracic disease · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Central airway obstruction (CAO) can be attributed to several benign or malignant conditions. Although surgery is the preferred therapeutic option for the management of CAO, bronchoscopic treatment can be performed in scenarios where the surgical procedure is not possible. Recent years have witnessed several improvements in the field of bronchoscopic treatment, especially with regard to airway stents. Current research involves new attempts to overcome the existing shortcomings pertaining to the stents (migration, mucostasis, and granulation tissue formation). The authors have recently developed a new silicone airway stent (GINA stent) with an anti-migration design, dynamic structure that enables the reduction of stent cross-sectional area, and radio-opacity. The present study aimed to evaluate the mechanical characteristics and performance of the novel GINA stent using a porcine tracheal stenosis model. In the current study, all the tests involved the comparison of the GINA stent [outer diameter (OD, mm): 14; length (L, mm): 55] with the Dumon stent (OD: 14; L: 50). The mechanical tests were performed using a digital force gauge, in order to determine the anti-migration force, expansion force, and flexibility. The present study evaluated the short-term (3 weeks) performance of the two stents after implantation [GINA (n = 4) vs. Dumon (n = 3)] in the porcine tracheal stenosis model. The results pertaining to the comparison of the mechanical properties of the GINA and Dumon stents are stated as follows: anti-migration force (18.4 vs. 12.8 N, P = 0.008); expansion force (11.9 vs. 14.5 N, P = 0.008); and flexibility (3.1 vs. 4.5 N, P = 0.008). The results pertaining to the comparison of the short-term performance of the GINA and Dumon stents are stated as follows: mucus retention (0/4 vs. 0/3); granulation tissue formation (0/4 vs. 0/3); and migration (1/4 vs. 2/3). The GINA stent displayed better mechanical properties and comparable short-term performance, compared to the Dumon stent.