ArticleMedical physics2021
Shape accuracy of fiber optic sensing for medical devices characterized in bench experiments.
Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 24 citations in OpenAlex.
- Mode-resolved picosecond single-photon polarimetry maps modal dynamics in multimode fibers.Nature communications · 2026Article
- Device-Specific Calibration Methods for Optical Frequency Domain Reflectometry-Based Shape Sensing in Catheters and Surgical Needles.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025Article
- Uncertainty Analysis of Fiber Optic Shape Sensing Under Core Failure.Sensors (Basel, Switzerland) · 2025Article
- Application of Mixed/Augmented Reality in Interventional Cardiology.Journal of clinical medicine · 2024Review
- Fiber Optic RealShape imaging using upper extremity and transfemoral access for fenestrated-branched endovascular aortic aneurysm repair.Journal of vascular surgery cases and innovative techniques · 2023Article
- 3D Visualisation of Navigation Catheters for Endovascular Procedures Using a 3D Hub and Fiber Optic RealShape Technology: Phantom Study Results.EJVES vascular forum · 2023Article
- Rayleigh-Based Distributed Optical Fiber Sensing.Sensors (Basel, Switzerland) · 2022Review
- Advanced Bronchoscopic Technologies for Biopsy of the Pulmonary Nodule: A 2021 Review.Diagnostics (Basel, Switzerland) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFiber Optic RealShape (FORS) is a new technology that visualizes the full three-dimensional shape of medical devices, such as catheters and guidewires, using an optical fiber embedded in the device. This three-dimensional shape provides guidance to clinicians during minimally invasive procedures, and enables intuitive navigation. The objective of this paper is to assess the accuracy of the FORS technology, as implemented in the current state-of-the-art Philips FORS system. The FORS system provides the shape of the entire device, including tip location and orientation. We consider all three aspects.
methodsIn bench experiments, we determined the accuracy of the location and orientation of the tip by displacing and rotating the fiber end, while allowing the rest of the fiber to change shape freely. To test the accuracy of the full shape, we have placed the fiber in a groove, which was accurately machined in a thick, stiff metal "path plate." We then compared the reconstructed shape with the known shape of the groove.
resultsThe tip location is found with submillimeter accuracy, and the orientation is sensed with milliradian accuracy. The shape of a fiber in the path plate faithfully follows the known shape of the groove, with typical deviation less than 0.5 mm in the plane of the plate. Out of plane accuracy, perhaps slightly less relevant clinically, is more challenging, due to the influence of twist; yet even out of the plane, the deviation is only submillimeter.
conclusionThe technology achieves submillimeter precision and provides full three-dimensional shape, surpassing the reported precision of other navigation and tracking technologies, and therefore may potentially alleviate the need for fluoroscopy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials