Evidence map›Paper›PMID 33843097›Full record

ArticleMedical physics2021

Shape accuracy of fiber optic sensing for medical devices characterized in bench experiments.

Mischa Megens, Merel D Leistikow, Anneke van Dusschoten, Martin B van der Mark, Jeroen J L Horikx, Elbert G van Putten, Gert W 't Hooft

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Device-Specific Calibration Methods for Optical Frequency Domain Reflectometry-Based Shape Sensing in Catheters and Surgical Needles.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025
    Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Rayleigh-Based Distributed Optical Fiber Sensing.Sensors (Basel, Switzerland) · 2022
    Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Mischa MegensIn-body Systems group, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Merel D LeistikowFORS Venture, Philips - Image Guided Therapy, 5684 PC, Best, The Netherlands.
Anneke van DusschotenIn-body Systems group, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Martin B van der MarkIn-body Systems group, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Jeroen J L HorikxIn-body Systems group, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Elbert G van PuttenFORS Venture, Philips - Image Guided Therapy, 5684 PC, Best, The Netherlands.
Gert W 't HooftIn-body Systems group, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Philips (Netherlands) · NLNXP (Netherlands) · NLPhilips (Finland) · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFiber Optic RealShape (FORS) is a new technology that visualizes the full three-dimensional shape of medical devices, such as catheters and guidewires, using an optical fiber embedded in the device. This three-dimensional shape provides guidance to clinicians during minimally invasive procedures, and enables intuitive navigation. The objective of this paper is to assess the accuracy of the FORS technology, as implemented in the current state-of-the-art Philips FORS system. The FORS system provides the shape of the entire device, including tip location and orientation. We consider all three aspects.

methodsIn bench experiments, we determined the accuracy of the location and orientation of the tip by displacing and rotating the fiber end, while allowing the rest of the fiber to change shape freely. To test the accuracy of the full shape, we have placed the fiber in a groove, which was accurately machined in a thick, stiff metal "path plate." We then compared the reconstructed shape with the known shape of the groove.

resultsThe tip location is found with submillimeter accuracy, and the orientation is sensed with milliradian accuracy. The shape of a fiber in the path plate faithfully follows the known shape of the groove, with typical deviation less than 0.5 mm in the plane of the plate. Out of plane accuracy, perhaps slightly less relevant clinically, is more challenging, due to the influence of twist; yet even out of the plane, the deviation is only submillimeter.

conclusionThe technology achieves submillimeter precision and provides full three-dimensional shape, surpassing the reported precision of other navigation and tracking technologies, and therefore may potentially alleviate the need for fluoroscopy.

Indexed as

Fiber Optic TechnologyOptical FibersFluoroscopydistributed optical fiber strain sensingnavigationoptical frequency domain reflectometryradiation freereal time

Identifiers

PMID33843097
PMCPMC9291042
OpenAlexW3152874437

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked