Evidence map›Paper›PMID 33842984›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022

Ultracongruent insert design is a safe alternative to posterior cruciate-substituting total knee arthroplasty: 5-year results of a randomized controlled trial.

Jörg Lützner, Franziska Beyer, Cornelia Lützner, Roman Riedel, Eric Tille

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jörg LütznerUniversity Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany. Joerg.Luetzner@ukdd.de.ORCID http://orcid.org/0000-0002-7162-828X
Franziska BeyerUniversity Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Cornelia LütznerUniversity Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Roman RiedelUniversity Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Eric TilleUniversity Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.

Funding

Aesculap STEADINESS
6 · The paper itself

Abstract

purposeIf substitution of the posterior cruciate ligament in total knee arthroplasty is necessary, there are two options available: posterior stabilized (PS) design with a post-cam mechanism or anterior-lipped ultracongruent (UC) inserts. UC inserts have the advantage that no femoral box is necessary and a standard femoral component can be used. The aim of this study was to compare the range of motion (ROM) and patient-reported outcome (PRO) after UC and PS fixed-bearing TKA. Better ROM in PS TKA and no difference in PRO between both designs was hypothesized.

methodsA randomized controlled trial with 127 patients receiving a fixed-bearing UC or PS design of the same knee system was performed. Nine patients died and there were four revision surgeries. 107 patients completed the 5-year follow-up. Patient-reported outcome was assessed. Patellofemoral problems were evaluated using selected applicable questions of the Oxford Knee Score (getting up from a table, kneeling, climbing stairs).

resultsSurgical time was 10 min shorter in the UC group (p < 0.001). After 5 years, both groups demonstrated good knee function and health-related quality of life without significant differences between the groups. Both groups demonstrated a high satisfaction score and the majority of patients would undergo this surgery again. Patellofemoral problems were recognized more frequently in the PS group (p = 0.025).

conclusionBoth designs demonstrated similar good results after 5 years. Stabilization with an anterior-lipped UC insert can be considered a safe alternative to the well-established PS design if cruciate substitution is necessary. LEVEL OF EVIDENCE: 1:

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneePosterior Cruciate LigamentHumansKnee JointProsthesis DesignQuality of LifeRange of Motion, ArticularAnterior stabilizedDeep dished insertPatient-reported outcomePosterior stabilizedRange of motionResultsStabilityTKATKRUltracongruent insert

Identifiers

PMID33842984
PMCPMC9418092

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.