Evidence map›Paper›PMID 33842243›Full record

ArticleGland surgery2021

A single-center, self-controlled, phase I clinical trial of mitoxantrone hydrochloride injection for lymph tracing for sentinel lymph node identification of breast cancer.

Benlong Yang, Shuyue Zheng, Xiaoyan Huang, Jiajian Chen, Zhebin Liu, Guangyu Liu, Shujun Wang, Zhimin Shao, Jiong Wu

Open access · diamondAbstract read
In one paragraph

Article in Gland surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Benlong YangDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Shuyue ZhengDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Xiaoyan HuangDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Jiajian ChenDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Zhebin LiuDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Guangyu LiuDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Shujun WangDepartment of Pharmacy, Shenyang Pharmaceutical University, Shenyang, China.
Zhimin ShaoDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Jiong WuDepartment of Breast Surgery, Fudan University Shanghai Cancer Center, Shanghai, China.
Fudan University Shanghai Cancer Center · CNShanghai Medical College of Fudan University · CNShenyang Pharmaceutical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMitoxantrone hydrochloride injection for lymph tracing (MHI) is a novel lymphatic tracer for sentinel lymph node (SLN) in patients with early breast cancer but exhibited remarkable liver, kidney, and hematologic toxicities in previous studies. Here, the pharmacokinetics and pharmacodynamics profiles of MHI were evaluated to surmise safety and tolerability.

methodsPhase 1 open-label, single center, and dose escalation study was performed. Ten patients with invasive breast cancer received 0.5, 1.0, or 2.0 mL of MHI into the breast tissues surrounding the tumor for lymphatic mapping. All of these patients were injected with 2 mCi nuclide-labeled sulfur colloid as a self-control 24 to 48 hours before surgery. Safety was assessed by the incidence of adverse events graded by the National Cancer Institute Common Terminology Criteria, version 4.0.3 (CTCAE4.0.3). Blood samples for pharmacokinetic analyses were collected before and after administration at 15, 30, 60, 120, and 240 min of the injection of MHI.

resultsUp to the cutoff date of the study (Aug 8, 2018), no dose-limiting toxic effects or obvious allergic reactions were observed. Only one case of an adverse event was certainly related to MHI, where it caused blue discoloration of the local skin over the injection site after the operation, but this stain gradually went away. The peak level of MHI was achieved after 15-30 min post injection and completely eliminated from the plasma after 60 min. There were no significant differences in the number of lymph nodes detected by MHI and radioactive colloid. Only one patient with lymph node macrometastases had no SLN detected by either the radioactive colloid or the MHI.

conclusionsAt a dose of up to 2.0 mL, MHI was well tolerated and safe for conducting SLN biopsies in patients with breast cancer. Although there was a case with blue discoloration of the local skin over the injection site after the operation, and remained for a short period of time, but the overall safety was acceptable. Here, we approached a novel SLN tracing slant; however, more investigations of MHI should be performed for further evaluations. (Chinadrugtrials.org.cn number: CXHL1301201, Date of registration: October 12, 2015.).

Indexed as

breast cancerlymphatic mappingMitoxantrone hydrochloridesentinel lymph node biopsy (SLNB)

Identifiers

PMID33842243
PMCPMC8033053
OpenAlexW3140622720

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.