ArticleJournal of infection prevention2021
DropSafe safety pen needle helps to prevent accidental needlesticks after injections: results of a simulated clinical study.
Article in Journal of infection prevention, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- Evaluation of different safety-engineered protection mechanisms of port access needles using a lifelike model of vascular access routes.Frontiers in medical technology · 2025Article
- Clinical Application of a Safe Blood Sampling Device with an Indwelling Needle.Applied bionics and biomechanics · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMost needlestick injuries (NSIs) result from unsafe needle devices. DropSafe safety pen needle (SPN) was designed to help prevent such injuries before, during and after use through a built-in sharps injury prevention feature (SIPF).
methodsA two-phase study was undertaken. For the pilot study, five non-healthcare users (NHCUs) performed evaluations. For the validation study, 30 evaluators comprising 10 healthcare professionals (HCPs) and 20 NHCUs performed evaluations. The aim of the study was to validate the performance of the SIPF of the SPN and to collect feedback from the evaluators on several aspects of the safety device. Participants performed simulated injections into an orange.
resultsThe results show that no device failures were observed, and all manipulations were performed without a needlestick or without contact with the needle after injection. The safety feature of the SPN was activated successfully. It was shown that: the label on the seal was legible; the SPNs were easy to attach to the pen injector; injections were easy to perform; it was clear when safety feature was activated; removing the SPN from the injection pen was easy; and the written instructions were easy to understand.
conclusionThe performance of the safety feature of SPN was successfully evaluated in terms of the prevention of NSIs. User feedback demonstrate that the device's ease of use, handling and instructions for use ensure safety and effectiveness of the SPN when used as intended.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials