ArticleActa neurochirurgica. Supplement2021
Comparison of Two Intracranial Pressure Calculation Methods and Their Effects on the Mean Intracranial Pressure and Intracranial Pressure Dose.
Article in Acta neurochirurgica. Supplement, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Accuracy of Manual Intracranial Pressure Recording Compared to a Computerized High-Resolution System: A CENTER-TBI Analysis.Neurocritical care · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study compared two methods of calculating the intracranial pressure (ICP) in a patient: end-hour ICP and hour-averaged ICP. A total of 1060 patients with traumatic brain injury and a known clinical outcome were studied. For each patient, the end-hour ICP and hour-averaged ICP were calculated. The mean ICP and the ICP dose above 20 mmHg were evaluated using both calculation methods. The results for patients who survived and those who died were compared using a Student's t test. The average correlation between the end-hour and hour-averaged mean ICP was 0.747, indicating that the end-hour ICP method agrees moderately with the hour-averaged method. However, the comparison between surviving and dead patients did not present significant differences between ICP values averaged with these two different methods. The Student's t test gave similar results for both the mean ICP and ICP dose. The results suggest that the end-hour and hour-averaged methods have similar predictive power for patients' clinical outcome.
Indexed as
Identifiers
33839813What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.