Evidence map›Paper›PMID 33838266›Full record

ArticleNeuroImage2021

Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system.

Matthew J Brookes, Elena Boto, Molly Rea, Vishal Shah, James Osborne, Niall Holmes, Ryan M Hill, James Leggett, Natalie Rhodes, Richard Bowtell

Abstract read
In one paragraph

Article in NeuroImage, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 64 papers.

0numbers the graph read from it
0cells of the map it votes in
64citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

64 citing papers in PubMed.

  1. Spatial-Jitter Model for Magnetoencephalography Sensor Arrays.IEEE transactions on medical imaging · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Enhanced Neural Decoding With Optically Pumped Magnetometer MEG Using Multivariate Pattern Analysis.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
  6. Article
  7. Potential ofEpilepsia open · 2025
    Article
  8. Article
  9. Article
  10. SPM-30 years and beyond.Cerebral cortex (New York, N.Y. : 1991) · 2025
    Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Wearable Magnetoencephalography in a Lightly Shielded Environment.IEEE transactions on bio-medical engineering · 2025
    Article
  16. Article
  17. Article
  18. Optimal configuration of on-scalp OPMs with fixed channel counts.Imaging neuroscience (Cambridge, Mass.) · 2025
    Article
  19. Article
  20. Article

4 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Matthew J BrookesSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom. Electronic address: matthew.brookes@nottingham.ac.uk.
Elena BotoSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
Molly ReaSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
Vishal ShahQuSpin Inc., 331 South 104th Street, Suite 130, Louisville, CO 80027, United States.
James OsborneQuSpin Inc., 331 South 104th Street, Suite 130, Louisville, CO 80027, United States.
Niall HolmesSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
Ryan M HillSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
James LeggettSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
Natalie RhodesSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
Richard BowtellSir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.

Funding

High-resolution Non-cryogenic Magnetoencephalography: Systems-Level IntegrationR44MH110288 · NIMH · QUSPIN · PI SHAH, VISHAL K · 2016 to 2022
$5.1M
Commercialization Readiness of Wearable Optically Pumped MagnetoencephalographySB1MH136846 · NIMH · QUSPIN · PI Vishal K Shah · 2024 to 2026
$3.9M
NIMH NIH HHS R44 MH110288NIMH NIH HHS SB1 MH136846Wellcome TrustWellcome Trust 203257/B/16/ZWellcome Trust 203257/Z/16/Z
6 · The paper itself

Abstract

The optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a "wearable" scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality. Although many studies have shown the efficacy of 'OPM-MEG', one relatively untapped advantage relates to improved array design. Specifically, OPMs enable the simultaneous measurement of magnetic field components along multiple axes (distinct from a single radial orientation, as used in most conventional MEG systems). This enables characterisation of the magnetic field vector at all sensors, affording extra information which has the potential to improve source reconstruction. Here, we conduct a theoretical analysis of the critical parameters that should be optimised for effective source reconstruction. We show that these parameters can be optimised by judicious array design incorporating triaxial MEG measurements. Using simulations, we demonstrate how a triaxial array offers a dramatic improvement on our ability to differentiate real brain activity from sources of magnetic interference (external to the brain). Further, a triaxial system is shown to offer a marked improvement in the elimination of artefact caused by head movement. Theoretical results are supplemented by an experimental recording demonstrating improved interference reduction. These findings offer new insights into how future OPM-MEG arrays can be designed with improved performance.

Indexed as

Magnetic PhenomenaModels, TheoreticalAdultArtifactsCerebral CortexComputer SimulationEquipment DesignHumansMagnetic FieldsMagnetoencephalographyMaleBeamformerMagnetoencephalographyMEGOPMOptically pumped magnetometerTriaxial sensor

Identifiers

PMID33838266
PMCPMC8249355

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.