ArticleSleep & breathing = Schlaf & Atmung2022
Home sleep apnea testing: an accuracy study.
Article in Sleep & breathing = Schlaf & Atmung, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 35 citations in OpenAlex.
- Utility of Belun Ring platform for the diagnosis of obstructive sleep apnea: a systematic review and meta-analysis.Sleep & breathing = Schlaf & Atmung · 2025Pooled it
- Clinical study of two mandibular advancement devices in the treatment of Obstructive Sleep Apnea: a pilot randomized controlled trial.BMC oral health · 2024Trial
- Transparent artificial intelligence-enabled interpretable and interactive sleep apnea assessment across flexible monitoring scenarios.Nature communications · 2025Article
- Quantifying the sources of discrepancy between total recording time and total sleep time in home sleep apnea testing: insights from home-based polysomnography.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025Observational
- Feasibility and usability of three consecutive nights with self-applied, home polysomnography.Journal of sleep research · 2025Article
- 2024 Position Statement on the Use of Different Diagnostic Methods for Sleep Disorders in Adults - Brazilian Sleep Association.Sleep science (Sao Paulo, Brazil) · 2024Article
- Sleep-disordered breathing diagnosis: a comprehensive audit of home sleep testing in real clinical settings.Sleep & breathing = Schlaf & Atmung · 2024Article
- Performance of Wrist-Worn Pulse Oximeter for the Screening of Obstructive Sleep Apnea.Iranian journal of otorhinolaryngology · 2024Article
- A Novel Design of an Oral Appliance for Monitoring Electromyograms of the Genioglossus Muscle in Obstructive Sleep Apnea Syndrome.Life (Basel, Switzerland) · 2024Article
- Effect of comprehensive rehabilitation on apnea hypopnea index in patients with obstructive sleep apnea: a protocol for randomized controlled trial.Sleep & breathing = Schlaf & Atmung · 2024Article
- Level 2 Polysomnography for the Diagnosis of Sleep Disorders: A Health Technology Assessment.Ontario health technology assessment series · 2024Article
- Article
- Acupuncture for hypertension with insomnia: Study protocol for a randomized, sham-controlled, subject-and-assessor-blinded trial.Frontiers in psychiatry · 2022Article
- Efficacy of portable sleep monitoring device in diagnosing central sleep apnea in patients with congestive heart failure.Frontiers in neurology · 2022Article
- Brazilian Thoracic Association Consensus on Sleep-disordered Breathing.Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia · 2022Article
- Characteristics of Obstructive Sleep Apnea Patients With Hypertension and Factors Associated With Autotitration Acceptance.Frontiers in psychiatry · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimThere are no studies comparing tests performed at home with those carried out in the laboratory, using the same device. The only studies that have been performed have compared the device used at home with the standard polygraph used in the laboratory. The purpose of this study was therefore to verify the accuracy of the home diagnosis of obstructive sleep apnea syndrome (OSAS) via unassisted type 2 portable polysomnography, compared with polysomnography using the same equipment in a sleep laboratory.
methodsTo avoid any possible order effect on the apnea-hypopnea index (AHI), we randomly created two groups of 20-total 40 patients, according to the test sequence. One of the groups had the first test at home and the second test in the laboratory (H-L); the other group had the first test in the laboratory and the second at home (L-H). The second test always took place on the night immediately following the first test. All polysomnographic monitoring was undertaken with the same equipment, an Embletta X100 system (Embla, Natus Inc., Middleton, USA). The Embletta X100 is a portable polygraph that records eleven polygraph signs: (1) electroencephalogram C4/A; (2) electroencephalogram O2/M1; (3) submental EMG; (4) electrooculogram of the right side; (5) nasal cannula (air flow); (6) respiratory effort against a plethysmographic chest strap; (7) respiratory effort against an abdominal plethysmographic belt; (8) heart rate; (9) saturation of oxyhemoglobin; (10) snoring; and (11) body position.
resultsThere was no difference in sleep efficiency between the group monitored in the laboratory and the group tested at home (p = 0.30). There was no difference in total sleep time (p = 0.11) or sleep latency (p = 0.52), or in the latency in phases N2 and N3 between the monitoring in the laboratory and at home (N2 p = 0.24; N3 p = 0.09). Some differences occurred regarding the PSG that took place at home, with longer duration of wake after sleep onset (WASO) and longer latency for REM sleep, due to failure of the patient to start the monitoring by pressing the "events" button on the device. In the distribution of sleep phases, there was no difference between the group monitored in the laboratory and the group tested at home.
conclusionResults from home sleep monitoring correlate well with the laboratory "gold standard" and may be an option for diagnosing OSAS in selected patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.