Evidence map›Paper›PMID 33835321›Full record

ArticleApplied microscopy2021

Automated 3D scoring of fluorescence in situ hybridization (FISH) using a confocal whole slide imaging scanner.

Ziv Frankenstein, Naohiro Uraoka, Umut Aypar, Ruth Aryeequaye, Mamta Rao, Meera Hameed, Yanming Zhang, Yukako Yagi

Open access · diamondAbstract read
In one paragraph

Article in Applied microscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Ziv FrankensteinDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA. frankenz@mskcc.org.
Naohiro UraokaDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Umut AyparDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Ruth AryeequayeDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Mamta RaoDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Meera HameedDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Yanming ZhangDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Yukako YagiDepartment of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Memorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
National Institutes of Health/National Cancer Institute P30CA008748NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

Fluorescence in situ hybridization (FISH) is a technique to visualize specific DNA/RNA sequences within the cell nuclei and provide the presence, location and structural integrity of genes on chromosomes. A confocal Whole Slide Imaging (WSI) scanner technology has superior depth resolution compared to wide-field fluorescence imaging. Confocal WSI has the ability to perform serial optical sections with specimen imaging, which is critical for 3D tissue reconstruction for volumetric spatial analysis. The standard clinical manual scoring for FISH is labor-intensive, time-consuming and subjective. Application of multi-gene FISH analysis alongside 3D imaging, significantly increase the level of complexity required for an accurate 3D analysis. Therefore, the purpose of this study is to establish automated 3D FISH scoring for z-stack images from confocal WSI scanner. The algorithm and the application we developed, SHIMARIS PAFQ, successfully employs 3D calculations for clear individual cell nuclei segmentation, gene signals detection and distribution of break-apart probes signal patterns, including standard break-apart, and variant patterns due to truncation, and deletion, etc. The analysis was accurate and precise when compared with ground truth clinical manual counting and scoring reported in ten lymphoma and solid tumors cases. The algorithm and the application we developed, SHIMARIS PAFQ, is objective and more efficient than the conventional procedure. It enables the automated counting of more nuclei, precisely detecting additional abnormal signal variations in nuclei patterns and analyzes gigabyte multi-layer stacking imaging data of tissue samples from patients. Currently, we are developing a deep learning algorithm for automated tumor area detection to be integrated with SHIMARIS PAFQ.

Indexed as

AlgorithmAutomatedConfocal whole slide imaging (WSI) scannerFluorescence in situ hybridization (FISH)Segmentation

Identifiers

PMID33835321
PMCPMC8035347
OpenAlexW3143826885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked