Evidence map›Paper›PMID 33833477›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2019

Fluorescence lifetime imaging with a single-photon SPAD array using long overlapping gates: an experimental and theoretical study.

Andrei Ardelean, Arin Can Ulku, Xavier Michalet, Edoardo Charbon, Claudio Bruschini

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Phasor-based widefield FLIM using a gated 512×512 single-photon SPAD imager.Proceedings of SPIE--the International Society for Optical Engineering · 2019
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andrei ArdeleanAQUA Laboratory, EPFL, 71b Rue de la Maladière, Neuchâtel, Switzerland.
Arin Can UlkuAQUA Laboratory, EPFL, 71b Rue de la Maladière, Neuchâtel, Switzerland.
Xavier MichaletDepartment of Chemistry and Biochemistry, UCLA, 607 Charles E. Young Drive East, Los Angeles, USA.
Edoardo CharbonAQUA Laboratory, EPFL, 71b Rue de la Maladière, Neuchâtel, Switzerland.
Claudio BruschiniAQUA Laboratory, EPFL, 71b Rue de la Maladière, Neuchâtel, Switzerland.

Funding

Single-photon counting APD arrays for high-through-put single-molecule assaysR01GM095904 · NIGMS · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI GHIONI, MASSIMO ANTONIO, MICHALET, XAVIER · 2012 to 2016
$2.0M
NIGMS NIH HHS R01 GM095904
6 · The paper itself

Abstract

Developing large arrays of single-photon avalanche diodes (SPADs) with on-chip time-correlated single-photon counting (TCSPC) capabilities continues to be a difficult task due to stringent silicon real estate constraints, high data rates and system complexity. As an alternative to TCSPC, time-gated architectures have been proposed, where the numbers of photons detected within different time gates are used as a replacement to the usual time-resolved luminescence decay. However, because of technological limitations, the minimum gate length implement is on the order of nanoseconds, longer than most fluorophore lifetimes of interest. However, recent FLIM measurements have shown that it is mainly the gate step and rise/fall time, rather than its length, which determine lifetime resolution. In addition, the large number of photons captured by longer gates results in higher SNR. In this paper, we study the effects of using long, overlapping gates on lifetime extraction by phasor analysis, using a recently developed 512×512 time-gated SPAD array. The experiments used Cy3B, Rhodamine 6G and Atto550 dyes as test samples. The gate window length was varied between 11.3 ns and 23 ns while the gate step was varied between 17.86 ps and 3 ns. We validated the results with a standard TCSPC setup and investigated the case of multi-exponential samples through simulations. Results indicate that lifetime extraction is not degraded by the use of longer gates, nor is the ability to resolve multi-exponential decays.

Indexed as

FLIMgated FLIMlong gatephasorSPAD

Identifiers

PMID33833477
PMCPMC8026147

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.