Evidence map›Paper›PMID 33832585›Full record

ArticleAnalytica chimica acta2021

Turn-on fluorescent probe for dopamine detection in solutions and live cells based on in situ formation of aminosilane-functionalized carbon dots.

Xiao-Yue Tang, Yi-Ming Liu, Xiao-Lin Bai, Hao Yuan, Yi-Kao Hu, Xiao-Ping Yu, Xun Liao

Open access · greenAbstract read
In one paragraph

Article in Analytica chimica acta, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Article
  3. Trends on Aerogel-Based Biosensors for Medical Applications: An Overview.International journal of molecular sciences · 2024
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Xiao-Yue TangChengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
Yi-Ming LiuDepartment of Chemistry and Biochemistry, Jackson State University, 1400 Lynch St., Jackson, MS, 39217, USA. Electronic address: yiming.liu@jsums.edu.
Xiao-Lin BaiChengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China.
Hao YuanChengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
Yi-Kao HuChengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
Xiao-Ping YuChengdu Medical College, Chengdu, 610083, China.
Xun LiaoChengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China. Electronic address: liaoxun@cib.ac.cn.
Chinese Academy of Sciences · CNChengdu Medical College · CNJackson State University · US

Funding

Strengthening the Biomedical Data Science Training Program at Jackson State UniversityU54MD015929 · NIMHD · JACKSON STATE UNIVERSITY · PI STEVENS, JACQUELINE JEANETTE · 2020 to 2024
$12.1M
NIMHD NIH HHS U54 MD015929
6 · The paper itself

Abstract

Dopamine (DA) is a critical biomarker for a variety of neurological diseases. Methods for simple and rapid DA detection are crucial for clinical diagnosis and treatments for those diseases. In this work, we developed a novel pretreatment-free method for dopamine detection using carbon dots as a turn-on fluorescent probe synthesized in situ. The aminosilane-functionalized carbon dots (SiCDs) were produced in a mild condensation reaction between N-[3-(Trimethoxysilyl)propyl]ethylenediamine (AEATMS) and dopamine, which were directly used for probing of dopamine. The prepared SiCDs exhibited green fluorescence with excitation/emission maximum at 380/495 nm, the intensity of which can be measured to quantify the DA present in the reaction mixture. The linear range of the assay was between 0.1 and 100 μM with a limit of detection (LOD) of 56.2 nM. The probe is of good selectivity and the recoveries of the developed method were in the range of 101.77-119.91% with RSDs within 3.67% in human serum sample tests. The SiCDs were also synthesized within MN9D cells under 37 °C and generated bright fluorescence, which can probe the DA's distribution in the cells. The described method exhibit potential in DA detection and live-cell imaging for its feature of facility, inexpensiveness, and sensitivity.

Indexed as

Fluorescent DyesQuantum DotsCarbonDopamineHumansLimit of DetectionCarbonDopamineFluorescent DyesCarbon dotsCell imagingDopamineFluorescent probeIn situ detection

Identifiers

PMID33832585
PMCPMC8066768
OpenAlexW3135942726

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.