Evidence map›Paper›PMID 33831814›Full record

ArticleComputers in biology and medicine2021

In-silico development and assessment of a Kalman filter motor decoder for prosthetic hand control.

Mai Gamal, Mohamed H Mousa, Seif Eldawlatly, Sherif M Elbasiouny

Open access · greenAbstract read
In one paragraph

Article in Computers in biology and medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Mai GamalCenter for Informatics Science, Nile University, Giza, Egypt; Computer Science and Engineering Department, Faculty of Media Engineering and Technology, German University in Cairo, Cairo, Egypt.
Mohamed H MousaDepartment of Biomedical, Industrial, and Human Factors Engineering, Wright State University, Dayton, OH, USA.
Seif EldawlatlyComputer Science and Engineering Department, Faculty of Media Engineering and Technology, German University in Cairo, Cairo, Egypt; Computer and Systems Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt.
Sherif M ElbasiounyDepartment of Biomedical, Industrial, and Human Factors Engineering, Wright State University, Dayton, OH, USA; Department of Neuroscience, Cell Biology, and Physiology, Wright State University, Dayton, OH, USA. Electronic address: sherif.elbasiouny@wright.edu.
Wright State University · USAin Shams University · EGCairo University · EG

Funding

The impact of neuromodulatory state on the excitability changes of motoneurons and the motor pool in ALSR01NS091836 · NINDS · WRIGHT STATE UNIVERSITY · PI Sherif M Elbasiouny · 2015 to 2026
$4.7M
NINDS NIH HHS R01 NS091836
6 · The paper itself

Abstract

Up to 50% of amputees abandon their prostheses, partly due to rapid degradation of the control systems, which require frequent recalibration. The goal of this study was to develop a Kalman filter-based approach to decoding motoneuron activity to identify movement kinematics and thereby provide stable, long-term, accurate, real-time decoding. The Kalman filter-based decoder was examined via biologically varied datasets generated from a high-fidelity computational model of the spinal motoneuron pool. The estimated movement kinematics controlled a simulated MuJoCo prosthetic hand. This clear-box approach showed successful estimation of hand movements under eight varied physiological conditions with no retraining. The mean correlation coefficient of 0.98 and mean normalized root mean square error of 0.06 over these eight datasets provide proof of concept that this decoder would improve long-term integrity of performance while performing new, untrained movements. Additionally, the decoder operated in real-time (~0.3 ms). Further results include robust performance of the Kalman filter when re-trained to more severe post-amputation limitations in the type and number of motoneurons remaining. An additional analysis shows that the decoder achieves better accuracy when using the firing of individual motoneurons as input, compared to using aggregate pool firing. Moreover, the decoder demonstrated robustness to noise affecting both the trained decoder parameters and the decoded motoneuron activity. These results demonstrate the utility of a proof of concept Kalman filter decoder that can support prosthetics' control systems to maintain accurate and stable real-time movement performance.

Indexed as

AmputeesArtificial LimbsAlgorithmsComputer SimulationHumansMovementDecodingFiring rateKalman filterMotoneuronsProsthetic control

Identifiers

PMID33831814
PMCPMC9887730
OpenAlexW3139233780

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.