Evidence map›Paper›PMID 33829705›Full record

ArticleSichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition2021

[The Application Value of Artificial Intelligence-based Filtering and Interpolated Image Reconstruction Algorithm in Abdominal Magnetic Resonance Image Denoising].

Xu Xu, Wan-Lin Peng, Jin-Ge Zhang, Ke-Ling Liu, Si-Xian Hu, Ling-Ming Zeng, Chun-Chao Xia, Zhen-Lin Li

Open access · greenAbstract read
In one paragraph

Article in Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 97% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Xu XuDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Wan-Lin PengDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Jin-Ge ZhangDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Ke-Ling LiuDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Si-Xian HuDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Ling-Ming ZengDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Chun-Chao XiaDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
Zhen-Lin LiDepartment of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
West China Hospital of Sichuan University · CNSichuan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the noise reduction performance of conventional filtering and artificial intelligence-based filtering and interpolation (AIFI) and to explore for optimal parameters of applying AIFI in the noise reduction of abdominal magnetic resonance imaging (MRI).

methodsSixty patients who underwent upper abdominal MRI examination in our hospital were retrospectively included. The raw data of T1-weighted image (T1WI), T2-weighted image (T2WI), and dualecho sequences were reconstructed with two image denoising techniques, conventional filtering and AIFI of different levels of intensity. The difference in objective image quality indicators, peak signal-to-noise ratio (pSNR) and image sharpness, of the different denoising techniques was compared. Two radiologists evaluated the image noise, contrast, sharpness, and overall image quality. Their scores were compared and the interobserver agreement was calculated.

resultsCompared with the original images, improvement of varying degrees were shown in the pSNR and the sharpness of the images of the three sequences, T1W1, T2W2, and dual echo sequence, after denoising filtering and AIFI were used (all

conclusionAIFI is superior to filtering in imaging denoising at medium and high levels. It is a promising noise reduction technique. The optimal parameters of using AIFI for abdominal MRI are Filtering+AIFI level=3 in the T1WI sequence and AIFI level=4 in T2WI and dualecho sequences.

Indexed as

Artificial IntelligenceMagnetic Resonance ImagingAlgorithmsHumansImage Processing, Computer-AssistedRetrospective StudiesAbdominal magnetic resonance imagingArtificial intelligenceFilteringImage denoising

Identifiers

PMID33829705
PMCPMC10408905
OpenAlexW3141402705

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.