Evidence map›Paper›PMID 33829151›Full record

ArticleACS applied nano materials2019

Combining High Sensitivity and Dynamic Range: Wearable Thin-Film Composite Strain Sensors of Graphene, Ultrathin Palladium, and PEDOT:PSS.

Julian Ramírez, Daniel Rodriquez, Armando Urbina, Anne Cardenas, Darren J Lipomi

Abstract read
In one paragraph

Article in ACS applied nano materials, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. A Review on the Use of Impedimetric Sensors for the Inspection of Food Quality.International journal of environmental research and public health · 2020
    Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Julian RamírezDepartment of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, CA 92093-0448.
Daniel RodriquezDepartment of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, CA 92093-0448.
Armando UrbinaDepartment of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, CA 92093-0448.
Anne CardenasDepartment of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, CA 92093-0448.
Darren J LipomiDepartment of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0448, La Jolla, CA 92093-0448.

Funding

Mentoring Young Minds to Increase Diversity in the Biomedical ResearchR25GM083275 · NIGMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DE MAIO, ANTONIO, LAWSON, MARK ANDREW · 2008 to 2022
$9.9M
Stretchable, Biodegradable, and Self-Healing Semiconductors for Wearable and Implantable SensorsDP2EB022358 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI LIPOMI, DARREN J · 2015 to 2020
$2.7M
NIBIB NIH HHS DP2 EB022358NIGMS NIH HHS R25 GM083275
6 · The paper itself

Abstract

Wearable mechanical sensors have the potential to transform healthcare by enabling patient monitoring outside of the clinic. A critical challenge in the development of mechanical-e.g., strain-sensors is the combination of sensitivity, dynamic range, and robustness. This work describes a highly sensitive and robust wearable strain sensor composed of three layered materials: graphene, an ultrathin film of palladium, and highly plasticized PEDOT:PSS. The role of the graphene is to provide a conductive, manipulable substrate for the deposition of palladium. When deposited at low nominal thicknesses (~8 nm) palladium forms a rough, granular film which is highly piezoresistive (i.e., the resistance increases with strain with high sensitivity). The dynamic range of these graphene/palladium films, however, is poor, and can only be extended to ~10% before failure. This fragility renders the films incompatible with wearable applications on stretchable substrates. To improve the working range of graphene/palladium strain sensors, a layer of highly plasticized PEDOT:PSS is used as a stretchable conductive binder. That is, the conductive polymer provides an alternative pathway for electrical conduction upon cracking of the palladium film and the graphene. The result was a strain sensor that possessed good sensitivity at low strains (0.001% engineering strain) but with a working range up to 86%. The piezoresistive performance can be optimized in a wearable device by sandwiching the conductive composite between a soft PDMS layer in contact with the skin and a harder layer at the air interface. When attached to the skin of the torso, the patch-like strain sensors were capable of detecting heartbeat (small strain) and respiration (large strain) simultaneously. This demonstration highlights the ability of the sensor to measure low and high strains in a single interpolated signal, which could be useful in monitoring, for example, obstructive sleep apnea with an unobtrusive device.

Indexed as

GrapheneMetallic NanoislandsSleep ApneaStrain SensorWearable Sensor

Identifiers

PMID33829151
PMCPMC8023279

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked