Evidence map›Paper›PMID 33828640›Full record

ArticleIEEE photonics journal2021

Dual-Illumination Ultrasound/ Photoacoustic System for Cervical Cancer imaging.

Maryam Basij, Andrei Karpiouk, Ira Winer, Stanislav Emelianov, Mohammad Mehrmohammadi

Open access · goldAbstract read
In one paragraph

Article in IEEE photonics journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 18 citations in OpenAlex.

  1. Review
  2. Article
  3. Characterization of adnexal lesions using photoacoustic imaging to improve sonographic O-RADS risk assessment.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2023
    Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Maryam BasijDepartment of Biomedical Engineering, Wayne State University, Detroit, MI, USA.
Andrei KarpioukSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
Ira WinerDepartment of Oncology, Wayne State University, Detroit, MI, USA.
Stanislav EmelianovSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
Mohammad MehrmohammadiDepartment of Biomedical Engineering, Wayne State University, Detroit, MI, USA.
Wayne State University · USGeorgia Institute of Technology · US

Funding

Molecular, Functional, and Microstructural Imaging of Cervical Remodeling BiomarkersR01EB030058 · NIBIB · WAYNE STATE UNIVERSITY · PI MEHRMOHAMMADI, MOHAMMAD · 2020 to 2023
$1.6M
NIBIB NIH HHS R01 EB030058
6 · The paper itself

Abstract

Early stage cancer detection technologies can provide functional information and potentially decrease the mortality rate caused by cervical cancer. In our previous work, a miniaturized ultrasound and photoacoustic endoscopic system has been developed to image the cervical tissue through the cervical canal to fulfills the need for a safe, low-cost, and high-resolution functional diagnostic system. However, the miniaturized size of endoscope and American National Standards Institute safety limits cause constraints of using high-intensity illumination during imaging. In addition, the strong light scattering of tissues limits the light penetration depth. Fortunately, the cervix anatomy allows for the delivery of additional light from the ectocervix by using an external illumination system. Here we propose a dual, co-planar illumination system, which can provide adequate illumination to the cervical tissue via combined internal and external light delivery strategies. Therefore, an increase in the area of light-tissue interaction allows us to raise the laser light energy while keeping fluence under safety limits. Thus, a reliable PA imaging can be obtained for the whole cervical tissue thickness. The system performance was tested using a Monte Carlo simulation, and laser-light fluence was calculated and compared at different depths within a simulated cervical-tissue model. The results indicated a higher and more uniform fluence in the Monte Carlo simulations. In addition, the photoacoustic imaging of the proposed system was evaluated by two cervical tissue-mimicking phantoms with human blood and graphite rods as inclusions inside it. In accordance with the simulations, the phantom study revealed a more reliable photoacoustic signal for the entire depth of the phantoms with an improved contrast to noise ratio and signal to noise ratio, and a higher coverage ratio of the imaging field of view. In summary, the dual-mode illumination system can provide more realistic information of inclusions within the tissue while considering safety limits, which can lead to more accuracy in biomarker detection for cervical cancer diagnostics.

Indexed as

Dual illuminationEndoscopefiber opticMonte-Carlophotoacousticside-firingultrasound

Identifiers

PMID33828640
PMCPMC8023629
OpenAlexW3113078596

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.