Evidence map›Paper›PMID 33825010›Full record

ArticleSurgical endoscopy2021

Initial experience using a handheld fully articulating software-driven laparoscopic needle driver in TAPP inguinal hernia repair.

Victoria Needham, Diego Camacho, Flavio Malcher

Open access · hybridAbstract read
In one paragraph

Article in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Victoria NeedhamDepartment of Surgery, Montefiore Medical Center, 111 East 210th Street, Bronx, NY, 10467, USA. vgilbert08@gmail.com.
Diego CamachoDepartment of Surgery, Montefiore Medical Center, 111 East 210th Street, Bronx, NY, 10467, USA.
Flavio MalcherDepartment of Surgery, Montefiore Medical Center, 111 East 210th Street, Bronx, NY, 10467, USA.
Montefiore Medical Center · USAlbert Einstein College of Medicine · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair is a widely performed minimally invasive operation, but can present considerable ergonomic challenges for the surgeon. Our objective was to determine if a novel handheld software-driven laparoscopic articulating needle driver can mitigate these difficulties.

methodsThe video recordings of a consecutive series of TAPP cases by a single surgeon using the articulating device were compared with a series of cases using straight-stick laparoscopy. Two critical steps of the procedure were analyzed for time: mesh fixation and peritoneal suture closure. These steps were then compared before and after 10 initial consecutive cases to analyze whether the surgeon demonstrated improvement. A cost analysis was also performed between the two techniques.

resultsFor mesh fixation, the surgeon averaged 227 s using tacker devices, compared with 462.4 s using the novel laparoscopic device (p = 0.06). For the peritoneal closure component of the operation, the surgeon improved the time per suture pass during closure from 60.61 s during the first 10 cases to 38.84 s after the first 10 cases (p = 0.0004), which was comparable to the time per stitch for standard laparoscopy (34.8 s vs 34.84 s, p = 0.997). Left-sided inguinal hernia repairs using the articulating device demonstrated a significantly longer time per stitch during peritoneal closure compared to the right side after first 10 cases (left: 40.62 s; right: 27.91, p = 0.005). Our direct cost analysis demonstrated that suture closure of the peritoneum using the articulating device was more cost-effective than tack fixation.

conclusionsAfter only a 10 case initial experience, a laparoscopic hand-held articulating needle driver is comparable to standard laparoscopy to complete suture mesh fixation and peritoneal closure for TAPP inguinal hernia repair. Further, the feasibility of suture mesh fixation minimizes the need for costly tacker devices. This instrument appears to be a promising tool in this largely minimally invasive era of hernia repair.

Indexed as

Hernia, InguinalLaparoscopyHerniorrhaphyHumansSoftwareSurgical MeshArticulating needle driverInguinal hernia repairLaparoscopic suturingLaparoscopyTAPP

Identifiers

PMID33825010
PMCPMC8116294
OpenAlexW3146640835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.