Evidence map›Paper›PMID 33824795›Full record

ArticleCureus2021

Development and Evaluation of an Automated Manual Resuscitator-Based Emergency Ventilator-Alternative.

Jesica Urbina, Stormy M Monks, Luis Ochoa, Robert F Stump, Ryan B Wicker, Chris Danek, Victor I Torres, Scott B Crawford

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Jesica UrbinaTraining and Educational Center for Healthcare Simulation (TECHS), Texas Tech University Health Sciences Center El Paso, El Paso, USA.
Stormy M MonksTraining and Educational Center for Healthcare Simulation (TECHS), Texas Tech University Health Sciences Center El Paso, El Paso, USA.
Luis OchoaW.M. Keck Center for 3D Innovation, The University of Texas at El Paso, El Paso, USA.
Robert F StumpEmergency Medicine, Texas Tech University Health Sciences Center El Paso, El Paso, USA.
Ryan B WickerW.M. Keck Center for 3D Innovation, The University of Texas at El Paso, El Paso, USA.
Chris DanekRegulatory Affairs, Bessel LLC, San Carlos, USA.
Victor I TorresTraining and Educational Center for Healthcare Simulation (TECHS), Texas Tech University Health Sciences Center El Paso, El Paso, USA.
Scott B CrawfordEmergency Medicine; Training and Educational Center for Healthcare Simulation (TECHS), Texas Tech University Health Sciences Center El Paso, El Paso, USA.
The University of Texas at El Paso · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mass casualty incidents such as those that are being experienced during the novel coronavirus disease (COVID-19) pandemic can overwhelm local healthcare systems, where the number of casualties exceeds local resources and capabilities in a short period of time. The influx of patients with lung function deterioration as a result of COVID-19 has strained traditional ventilator supplies. To bridge the gap during ventilator shortages and to help clinicians triage patients, manual resuscitator devices can be used to deliver respirations to a patient requiring breathing support. Bag-valve mask (BVM) devices are ubiquitous in ambulances and healthcare environments, however require a medical professional to be present and constantly applying compression to provide the patient with respirations. We developed an automated manual resuscitator-based emergency ventilator-alternative (AMREV) that provides automated compressions of a BVM in a repetitive manner and is broadly compatible with commercially-available BVM devices approximately 5 inches (128 mm) in diameter. The AMREV device relieves the medical professional from providing manual breathing support and allows for hands-free operation of the BVM. The AMREV supports the following treatment parameters: 1) adjustable tidal volume (V

Indexed as

automated bvm compression devicebag valve maskemergency ventilatormanual resuscitatormechanical ventilator

Identifiers

PMID33824795
PMCPMC8012105
OpenAlexW3135696991

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked