ArticleInternational journal of burns and trauma2021
Technical difficulties and mechanical failure of distal femoral locking compression plate (DFLCP) in management of unstable distal femoral fractures.
Article in International journal of burns and trauma, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- Does dual-plating offer superior stability in complex distal femoral fracture management?Journal of orthopaedic surgery and research · 2026Observational
- Comparative study of double and single plate fixation for distal femur fractures.Bioinformation · 2026Article
- The impact of medial-first dual plating for reduction of distal femoral fractures: a retrospective comparative cohort study.Scientific reports · 2025Article
- Effectiveness of the Dorr index in predicting implant failure before proximal femoral nail application.Joint diseases and related surgery · 2025Article
- Management of distal femoral fractures with metaphyseal and articular comminution (AO/OTA 33C) using nail and plate fixation: a technical note and case series of 14 patients.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective of the paper is to portray the technical difficulties and mechanical failure of Distal Femoral Locking Compression Plate in the management of unstable distal femoral fractures. The primary outcome measure was defined as revision surgery due to implant failure with subsequent non-union. Secondary outcome measures were mal-union, delayed union, peri-implant fracture and infection. Functional outcome were evaluated using Schatzker & Lambert criteria. Thirty nine patients were available for final follow up. The rate of revision surgery as primary outcome measure was 7.69%. Mal-union was seen in 5.1%, delayed union in 7.69%, superficial infection in 10.25% and deep infection in 5.1% patients. All except three fractures united following index surgery. Functional outcome as per the Schatzker & Lambert Criteria was excellent in 20.5%, good in 48.7%, fair in 18% and failure in 12.8%. In sight of the findings of our study along with existing literature we propose for creating a fixation construct that is conducive for fracture healing by following principles of locking compression plating and augmenting stability by medial column reconstruction.
Indexed as
Identifiers
33824780PMC8012867W3143024782What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.