ArticleBMC anesthesiology2021
Simultaneous comparison of depth of sedation performance between SedLine and BIS during general anesthesia using custom passive interface hardware: study protocol for a prospective, non-blinded, non-randomized trial.
Article in BMC anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03865316 (Comparison of Depth of Sedation Performance Between SedLine and Comparator Device During General Anesthesia), which is not on this map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of Depth of Sedation Performance Between SedLine and Comparator Device During General Anesthesia
Who cites it
14 citing papers in PubMed, 16 citations in OpenAlex.
- Motion Neural Monitoring Based on Flexible Materials: From Signal Acquisition to Training Enhancement.ACS omega · 2026Review
- EEG-Derived Entropy Monitoring During Propofol Sedation for ERCP: Sedation Profiles, Age-Related Effects, and Implications for Procedure-Specific Target Ranges.Medicina (Kaunas, Lithuania) · 2026Observational
- Comparative analysis of processed EEG indices and entropy-based metrics for assessing anesthetic depth: a scoping review - PRISMA-ScR.BMC biomedical engineering · 2026Article
- Difficulty Controlling Sedation Level Using Processed Electroencephalography Monitoring in a Patient With Intellectual Disability, Fontan Circulation, and a Severe Gag Reflex.Anesthesia progress · 2025Article
- Recent applications of EEG-based brain-computer-interface in the medical field.Military Medical Research · 2025Review
- Invasive and non-invasive monitoring in the ICU.Trauma surgery & acute care open · 2025Review
- Comparative Efficacy of Intraoperative Patient State Index vs. Bi-Spectral Index in Patients Undergoing Elective Spine Surgery with Neuromonitoring Under General Anaesthesia: A Randomized Controlled Trial.Turkish journal of anaesthesiology and reanimation · 2024Article
- Review
- Assessment of seizure duration and utility of using SedLineJournal of anesthesia, analgesia and critical care · 2024Article
- A Deep Learning Framework for Anesthesia Depth Prediction from Drug Infusion History.Sensors (Basel, Switzerland) · 2023Article
- Application of Bispectral Index System (BIS) Monitor to Ambulatory Pediatric Dental Patients under Intravenous Deep Sedation.Diagnostics (Basel, Switzerland) · 2023Article
- Cerebral Tissue Oxygen Saturation Correlates with Emergence from Propofol-Remifentanil Anesthesia: An Observational Cohort Study.Journal of clinical medicine · 2022Article
- Signatures of Thalamocortical Alpha Oscillations and Synchronization With Increased Anesthetic Depths Under Isoflurane.Frontiers in pharmacology · 2022Article
- The safety and efficacy of esketamine in comparison to dexmedetomidine during drug-induced sleep endoscopy in children with obstructive sleep apnea hypopnea syndrome: A randomized, controlled and prospective clinical trial.Frontiers in pharmacology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIntraoperative brain function monitoring with processed electroencephalogram (EEG) indices, such as the bispectral index (BIS) and patient state index (PSI), may improve characterization of the depth of sedation or anesthesia when compared to conventional physiologic monitors, such as heart rate and blood pressure. However, the clinical assessment of anesthetic depth may not always agree with available processed EEG indices. To concurrently compare the performance of BIS and SedLine monitors, we present a data collection system using shared individual generic sensors connected to a custom-built passive interface box.
methodsThis prospective, non-blinded, non-randomized study will enroll 100 adult American Society of Anesthesiologists (ASA) class I-III patients presenting for elective procedures requiring general anesthesia. BIS and SedLine electrodes will be placed preoperatively according to manufacturer recommendations and their respective indices tracked throughout anesthesia induction, maintenance and emergence. The concordance between processed EEG indices and clinical assessments of anesthesia depth will be analyzed with chi-square and kappa statistic. DISCUSSION: Prior studies comparing brain function monitoring devices have applied both sensors on the forehead of study subjects simultaneously. With limited space and common sensor locations between devices, it is not possible to place both commercial sensor arrays according to the manufacturer's recommendations, thus compromising the validity of these comparisons. This trial utilizes a custom interface allowing signals from sensors to be shared between BIS and SedLine monitors to provide an accurate comparison. Our results will also characterize the degree of agreement between processed EEG indices and clinical assessments of anesthetic depth as determined by the anesthesiologists' interpretations of acute changes in blood pressure and heart rate as well as the administration, or change to the continuous delivery, of medications at these timepoints. Patient factors (such as burst suppression state or low power EEG conditions from aging brain), surgical conditions (such as use of electrocautery), artifacts (such as electromyography), and anesthesia medications and doses (such as end-tidal concentration of volatile anesthetic or hypnotic infusion dose) that lead to lack of agreement will be explored as well.
trial registrationClinical Trials ( ClinicalTrials.gov ), NCT03865316 . Registered on 4 February 2019 - retrospectively registered. SPONSOR: Masimo Corporation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.