Evidence map›Paper›PMID 33818178›Full record

ArticleInnovations (Philadelphia, Pa.)

Numerical Biomechanics Models of the Interaction Between a Novel Transcatheter Mitral Valve Device and the Subvalvular Apparatus.

Gil Marom, Romina Plitman Mayo, Nadav Again, Ehud Raanani

Open access · hybridAbstract read
In one paragraph

Article in Innovations (Philadelphia, Pa.). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Clinical Impact of Computational Heart Valve Models.Materials (Basel, Switzerland) · 2022
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Gil Marom26745 School of Mechanical Engineering, Tel Aviv University, Israel.
Romina Plitman Mayo26745 School of Mechanical Engineering, Tel Aviv University, Israel.
Nadav AgainThe Sheba Fund for Health Services and Research, Tel Hashomer, Israel.
Ehud Raanani26744 Leviev Cardiothoracic and Vascular Center, Chaim Sheba Medical Center, Tel Hashomer, Israel.
Sheba Medical Center · ILTel Aviv University · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveMitral valve regurgitation (MR) is a common valvular heart disease where improper closing causes leakage. Currently, no transcatheter mitral valve device is commercially available. Raanani (co-author) and colleagues have previously proposed a unique rotational implantation, ensuring anchoring by metallic arms that pull the chordae tendineae. This technique is now being implemented in a novel device design. The aim of this study is to quantify the rotational implantation effect on the mitral annulus kinematics and on the stresses in the chordae and papillary muscles.

methodsFinite element analysis of the rotational step of the implantation in a whole heart model is employed to compare 5 arm designs with varying diameters (25.9 mm to 32.4 mm) and rotation angles (up to 140°). The arm rotation that grabs the chordae was modeled when the valve was in systolic configuration.

resultsAn increase in the rotation angle results in reduced mitral annulus perimeters. Larger rotation angles led to higher chordae stresses with the 29.8 mm experiencing the maximum stresses. The calculated chordae stresses suggest that arm diameter should be <27.8 mm and the rotation angle <120°.

conclusionsThe upper limit of this diameter range is preferred in order to reduce the stresses in the papillary muscles while grabbing more chords. The findings of this study can help improving the design and performance of this unique device and procedural technique.

Indexed as

Mitral ValveMitral Valve InsufficiencyBiomechanical PhenomenaChordae TendineaeHumansPapillary Musclesbiomechanicscardiovascular devicesfinite element analysisheart valvesnumerical modelstranscatheter mitral valve

Identifiers

PMID33818178
PMCPMC8414811
OpenAlexW3142230986

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.