Evidence map›Paper›PMID 33814671›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2021

Evaluation of methods to derive blood flow velocity from 1000 fps high-speed angiographic sequences (HSA) using optical flow (OF) and computational fluid dynamics (CFD).

A Shields, S V Setlur Nagesh, C Ionita, D R Bednarek, S Rudin

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. First In-Vivo demonstration of 1000fps High Speed Coronary Angiography (HSCA) in a swine animal model.Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Simultaneous Biplane High Speed 1000 fps X-ray Angiography (HSAngio).Proceedings of SPIE--the International Society for Optical Engineering
    Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

A ShieldsCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
S V Setlur NageshCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
C IonitaCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
D R BednarekCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
S RudinCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.

Funding

High Speed Angiography at 1000 frames per secondR01EB030092 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB030092
6 · The paper itself

Abstract

Digital Subtraction Angiography (DSA) is considered the gold standard for imaging and guiding treatment of neurovascular lesions, such as cerebral aneurysms and carotid stenoses. Though DSA can show high-resolution morphology, it remains difficult to extract temporal physiological information, because higher frame-rates are necessary to accurately quantify neurovascular flow details. Recent advances in photon-counting detector technology have led us to develop High-Speed Angiography (HSA), where X-ray images are acquired at 1000 fps for more accurate visualization and quantification of blood flow. Blood flow was imaged using HSA under constant flow conditions within various 3D printed patient-specific phantoms. Blood velocity was quantified using an open source Optical Flow algorithm, OpenOpticalFlow, to perform velocity estimation based on the spatio-temporal intensity changes of iodinated contrast wavefronts. The results of these algorithms are then compared with Computational Fluid Dynamics (CFD) simulations, using the same inlet boundary conditions and model geometries. The performance of these algorithms at lower temporal resolution was then also assessed by simulating lower frame rates from the acquired 1000 fps data. It is important to ascertain the hemodynamic effect of abnormal neurovascular conditions, as well as their effect on treatment of such conditions during the actual clinical interventional procedure. While theoretical CFD results requiring considerable computer capability are delayed for hours or more, it is expected that clinical results from multiple HSA sequences will be available almost immediately while the patient is still under treatment, and even right after flow conditions are changed beneficially by the intervention.

Indexed as

Computational Fluid DynamicsHigh-Speed AngiographyNeurointerventional RadiologyNeurovascular DiseaseOptical FlowPhoton-Counting Detectors

Identifiers

PMID33814671
PMCPMC8018699

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.