Evidence map›Paper›PMID 33814586›Full record

ArticleIndian journal of anaesthesia2021

Comparative evaluation of Air-Q blocker and Proseal laryngeal mask airway in patients undergoing elective surgery under general anaesthesia: A randomised controlled trial.

Swati Jindal, Ankita Mittal, Lakesh K Anand, Manpreet Singh, Dheeraj Kapoor

Registry-linked trialOpen access · diamondAbstract read
In one paragraph

Article in Indian journal of anaesthesia, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06914453 (A Comparative Study of Air-Q3 and Ambu AuraGain Supraglottic Airway Device in Patients Undergoing Elective Surgery Under General Anaesthesia), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06914453 nacompletednot on this mapstarted 2024, after this paper: background citation

A Comparative Study of Air-Q3 and Ambu AuraGain Supraglottic Airway Device in Patients Undergoing Elective Surgery Under General Anaesthesia: A Randomised Controlled Trial

TypeinterventionalSponsorUniversity of MalayaRan2024 to 2025Enrolled90ConditionsOropharyngeal Leak Pressure, Supraglottic Airway, Elective Surgery, General AnaesthesiaArmsAir Q-3 Supraglottic Airway Device, Ambu AuraGain Supraglottic Airway Device
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Swati JindalDepartment of Anaesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, India.
Ankita MittalDepartment of Anaesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, India.
Lakesh K AnandDepartment of Anaesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, India.
Manpreet SinghDepartment of Anaesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, India.
Dheeraj KapoorDepartment of Anaesthesia and Intensive Care, Government Medical College and Hospital, Sector 32, Chandigarh, India.
Government Medical College and Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsThe Air-Q blocker (Cook gas LLC, Mercury Medical, Clearwater, FL, USA) is a relatively new supraglottic airway device (SAD) with capability to serve as a conduit for intubation. As there is limited data on Air-Q blocker, the present study was performed to compare the efficacy of Air-Q blocker and Proseal laryngeal mask airway (PLMA) in patients undergoing elective surgery.

methodsA total of 90 American Society of Anesthesiologists (ASA) physical status I and II patients were randomly allocated to Air-Q blocker or PLMA group. Oropharyngeal leak pressure (OLP), insertion success, insertion time, ease of orogastric tube (OGT) insertion, fibreoptic visualisation of the glottis, haemodynamic and ventilation parameters, and complications at emergence and postoperatively were investigated.

resultsOLPs were higher in PLMA group as compared to Air-Q blocker group (

conclusionsAir-Q blocker provides a clinically effective OLP though PLMA provides a slightly better sealing function in patients undergoing laparoscopic and non-laparoscopic surgeries under general anaesthesia requiring neuromuscular blockade. Air-Q blocker has shorter insertion time and a better fibreoptic view of glottis as compared to PLMA.

Indexed as

Air-Q blockergeneral anaesthesialaryngeal masksproseal laryngeal mask airway

Identifiers

PMID33814586
PMCPMC7993039
OpenAlexW3137240024

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.