ArticleJACC. Clinical electrophysiology2021
Epiphenomenal Re-Entry and Spurious Focal Activation Detection by Atrial Fibrillation Mapping Algorithms.
Article in JACC. Clinical electrophysiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Maintenance of atrial fibrillation by reciprocal triggering of competitive focal sources: a hypothesis.Frontiers in cardiovascular medicine · 2026Review
- Electrographic Flow Mapping Provides Prognosis for AF Ablation Outcomes Across Two Independent Prospective Patient Cohorts.Journal of clinical medicine · 2025Article
- "Pharmacological" analysis of atrial fibrillation maintenance mechanism: reentry, wavelets, or focal?Frontiers in cardiovascular medicine · 2025Review
- Statistics and behavior of clinically significant extra-pulmonary vein atrial fibrillation sources: machine-learning-enhanced electrographic flow mapping in persistent atrial fibrillation.Frontiers in cardiovascular medicine · 2025Article
- Electrographic flow mapping of atrial fibrillation.Current opinion in cardiology · 2025Review
- Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth'.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023Article
- Electrographic flow mapping for atrial fibrillation: theoretical basis and preliminary observations.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023Review
- Visualization of electrographic flow fields of increasing complexity and detection of simulated sources during spontaneously persistent AF in an animal model.Frontiers in cardiovascular medicine · 2023Article
- The hunt for extra-pulmonary vein targets in persistent atrial fibrillation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022Article
- Hybrid machine learning to localize atrial flutter substrates using the surface 12-lead electrocardiogram.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2022Article
- Left atrial anatomical variations correlate with atrial fibrillation sources near the left atrial ridge.Frontiers in cardiovascular medicine · 2022Article
Corrections and comments
- Commented on by
Authors and funding
4 authors.
Funding
Abstract
objectivesThe purpose of this study was to validate the ability of mapping algorithms to detect rotational activations (RoA) and focal activations (FoA) during fibrillatory conduction (FC) and atrial fibrillation (AF) and understand their mechanistic relevance.
backgroundMapping algorithms have been proposed to detect RoA and FoA to guide AF ablation.
methodsRapid left atrial pacing created FC-fibrillatory electrograms-with and without AF induction in dogs (n = 17). Activation maps were constructed using Topera (Abbott, St. Paul, Minnesota) or CARTOFINDER (Biosense Webster, Irvine, California) algorithms. Mapping strategies included: panoramic noncontact mapping with a basket catheter (CARTOFINDER n = 6, Topera n = 5); and sequential contact mapping using 8-spline OctaRay catheter (Biosense Webster) (n = 6). Offline frequency and spectral analysis were also performed. Algorithm-detected RoA was manually verified.
resultsThe right atrium (RA) consistently exhibited fibrillatory signals during FC. FC with and without AF had similar left-to-right frequency gradients. Basket maps were either uninterpretable (847 of 990 Topera, 132 of 148 Cartofinder) or had unverifiable RoA. OctaRay contact mapping showed 4% RoA (n = 30 of 679) and 63% FoA (n = 429 of 679). Verified RoA clustered at consistent sites, was more common in the RA than left atrium (odds ratio: 3.5), and colocalized with sites of frequency breakdown in the crista terminalis and RA appendage. During pacing, spurious FoA sites were identified around the atria, but not at the actual pacing sites. RoA and FoA site distribution was similar during pacing with and without induction, and during induced AF.
conclusionsMapping algorithms were unable to detect pacing sites as true drivers of FC, and detected epiphenomenal RoA and FoA sites unrelated to AF induction or maintenance. Algorithm-detected RoA and FoA did not identify true AF drivers.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.