ArticlePatient safety in surgery2021
Incidence and OR team awareness of "near-miss" and retained surgical sharps: a national survey on United States operating rooms.
Article in Patient safety in surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 16 citations in OpenAlex.
- Identifying a list of healthcare 'never events' to effect system change: a systematic review and narrative synthesis.BMJ open quality · 2023Pooled it
- Interventions for the Prevention of Retained Surgical Items: A Systematic Review.World journal of surgery · 2022Pooled it
- Perioperative Nursing Management of Unintended Retained Foreign Object-Related Events in Neurosurgery: Insights From a 16-Year Study in China.Journal of nursing management · 2026Article
- Nursing near miss: a concept analysis.BMC nursing · 2025Article
- Artificial intelligence model for automated surgical instrument detection and counting: an experimental proof-of-concept study.Patient safety in surgery · 2024Article
- A deep learning model based on fusion images of chest radiography and X-ray sponge images supports human visual characteristics of retained surgical items detection.International journal of computer assisted radiology and surgery · 2023Article
- Multiphase preclinical assessment of a novel device to locate unintentionally retained surgical sharps: a proof-of-concept study.Patient safety in surgery · 2023Article
- Current strategies to diagnose and manage positive surgical margins and local recurrence after partial nephrectomy.Asian journal of urology · 2022Review
- The role of teamwork and non-technical skills for improving emergency surgical outcomes: an international perspective.Patient safety in surgery · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionA retained surgical sharp (RSS) is a never event and defined as a lost sharp (needle, blade, instrument, guidewire, metal fragment) that is not recovered prior to the patient leaving the operating room. A "near-miss" sharp (NMS) is an intraoperative event where there is a lost surgical sharp that is recovered prior to the patient leaving the operating room. With underreporting of such incidents, it is unrealistic to expect aggressive development of new prevention and detection strategies. Moreover, awareness about the issue of "near-miss" or retained surgical sharps remains limited. The aim of this large-scale national survey-based study was to estimate the incidence of these events and to identify the challenges surrounding the use of surgical sharps in daily practice.
methodsWe hypothesized that there was a larger number of RSS and NMS events than what was being reported. We survived the different OR team members to determine if there would be discordance in reported incidence between groups and to also evaluate for user bias. An electronic survey was distributed to OR staff between December 2019 and April 2020. Respondents included those practicing within the United States from both private and academic institutions. Participants were initially obtained by designating three points of contact who identified participants at their respective academic institutions and while attending specialty specific medical conferences. Together, these efforts totaled 197 responses. To increase the number of respondents, additional emails were sent to online member registries. Approximately 2650 emails were sent resulting in an additional 250 responses (9.4% response rate). No follow up reminders were sent. In total, there were 447 survey responses, in which 411 were used for further analysis. Thirty-six responses were removed due to incomplete respondent data. Those who did not meet the definition of one of the three categories of respondents were also excluded. The 411 were then categorized by group to include 94 (22.9%) from anesthesiologist, 132 (32.1%) from resident/fellow/attending surgeon and 185 (45%) from surgical nurse and technologist. SURVEY: The survey was anonymous. Participants were asked to answer three demographic questions as well as eight questions related to their personal perception of NMS and RSS (Fig. 1). Demographic questions were asked with care to ensure no identifiable information was obtained and therefore unable to be traced back to a specific respondent or institution. Perception questions 4-6 and 11 were designed to understand the incidence of various sharp events (e.g. lost, retained, miscounted). Questions 7 and 10 were dedicated to understanding time spent managing sharps and questions 8 and 9 were dedicated to understanding the use x-ray and its effectiveness.
resultsOverall, most of each respondent group reported 1-5 lost sharp events over the last year. Roughly 20% of surgeons believed they never had a miscounted sharp over the last year, where only 5.3% of anesthesiologist reported the same (p = 0.002). Each group agreed that roughly 4 lost events occur every 1000 surgeries, but a significant difference was found between the three groups regarding the number of lost sharps not recovered per 10,000 surgeries with anesthesiologist, surgeon and nurse/technologist groups estimating 2.37, 2.56 and 2.94 respectively (p = 0.001). All groups noted x-ray to offer poor effectiveness at 26-50% with 31-40 min added for each time x-ray was used. More than half (56.8%) of surgeons reported using x-ray 100% of the time when managing a lost sharp whereas anesthesiologists and nurses/technologists believe it is closer to 1/3 of the time. An average of 21-30 min is spent managing each NMS, making a lost sharp event result in up to 70 min of added OR time.
conclusions"Near-miss" and RSS are more prevalent than what is reported in current literature. Surgeons perceive a higher rate of success in retrieving the RSS when compared to anesthesiologists and OR nurses/technologists. We recognize several challenges surrounding "near-miss" and never events as contributing factors to their underreported nature and the higher degree of surgeon recall bias associated with these events. Additionally, we highlight that current methods for prevention are costly in time and resources without improvement in patient safety. As NMS and RSS have significant health system implications, a strong understanding of these implications is important as we strive to improve patient safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.