Evidence map›Paper›PMID 33810187›Full record

ArticleSensors (Basel, Switzerland)2021

Towards Precise Interpretation of Oil Transformers via Novel Combined Techniques Based on DGA and Partial Discharge Sensors.

Sayed A Ward, Adel El-Faraskoury, Mohamed Badawi, Shimaa A Ibrahim, Karar Mahmoud, Matti Lehtonen, Mohamed M F Darwish

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sayed A WardFaculty of Engineering, Delta University for Science and Technology, Mansoura 11152, Egypt.
Adel El-FaraskouryExtra High Voltage Research Centre, Egyptian Electricity Holding Company, Cairo 11517, Egypt.
Mohamed BadawiDepartment of Electrical Engineering, Shoubra Faculty of Engineering, Benha University, Cairo 11629, Egypt.
Shimaa A IbrahimDepartment of Electrical Engineering, Shoubra Faculty of Engineering, Benha University, Cairo 11629, Egypt.
Karar MahmoudDepartment of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 02150 Espoo, Finland.ORCID 0000-0002-6729-6809
Matti LehtonenDepartment of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 02150 Espoo, Finland.ORCID 0000-0002-9979-7333
Mohamed M F DarwishDepartment of Electrical Engineering, Shoubra Faculty of Engineering, Benha University, Cairo 11629, Egypt.ORCID 0000-0001-9782-8813

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Power transformers are considered important and expensive items in electrical power networks. In this regard, the early discovery of potential faults in transformers considering datasets collected from diverse sensors can guarantee the continuous operation of electrical systems. Indeed, the discontinuity of these transformers is expensive and can lead to excessive economic losses for the power utilities. Dissolved gas analysis (DGA), as well as partial discharge (PD) tests considering different intelligent sensors for the measurement process, are used as diagnostic techniques for detecting the oil insulation level. This paper includes two parts; the first part is about the integration among the diagnosis results of recognized dissolved gas analysis techniques, in this part, the proposed techniques are classified into four techniques. The integration between the different DGA techniques not only improves the oil fault condition monitoring but also overcomes the individual weakness, and this positive feature is proved by using 532 samples from the Egyptian Electricity Transmission Company (EETC). The second part overview the experimental setup for (66/11.86 kV-40 MVA) power transformer which exists in the Egyptian Electricity Transmission Company (EETC), the first section in this part analyzes the dissolved gases concentricity for many samples, and the second section illustrates the measurement of PD particularly in this case study. The results demonstrate that precise interpretation of oil transformers can be provided to system operators, thanks to the combination of the most appropriate techniques.

Indexed as

dissolved gas analysisinsulating oilpartial dischargePD sensorpower transformer

Identifiers

PMID33810187
PMCPMC8005011

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.