Evidence map›Paper›PMID 33809223›Full record

ArticleMaterials (Basel, Switzerland)2021

Impact of Power Transformer Oil-Temperature on the Measurement Uncertainty of All-Acoustic Non-Iterative Partial Discharge Location.

Vladimir Polužanski, Nenad Kartalović, Boško Nikolić

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Vladimir PolužanskiSchool of Electrical Engineering, University of Belgrade, 73 Kralja Aleksandra Boulevard, 11120 Belgrade, Serbia.ORCID 0000-0002-4094-4044
Nenad KartalovićElectrical Engineering Institute of Nikola Tesla, University of Belgrade, 8a Koste Glavinica Street, 11040 Belgrade, Serbia.
Boško NikolićSchool of Electrical Engineering, University of Belgrade, 73 Kralja Aleksandra Boulevard, 11120 Belgrade, Serbia.ORCID 0000-0003-1142-9243

Funding

Ministry of Education, Science, and Technological Development of the Republic of Serbia TR33017
6 · The paper itself

Abstract

In this paper, the influence of the variation in transformer oil temperature on the accuracy of the all-acoustic non-iterative method for partial discharge location in a power transformer is researched. The research can improve power transformers' testing and monitoring, particularly given the large transformer oil temperature variations during real-time monitoring. The research is based on quantifying the contribution of oil temperature to the standard combined measurement uncertainty of the non-iterative algorithm by using analytical, statistical, and Monte Carlo methods. The contribution can be quantified and controlled. The contribution varied significantly with different mutual placements of partial discharge and acoustic sensors. The correlation between the contribution and the mean distance between partial discharge and acoustic sensors was observed. Based on these findings, the procedure to quantify and control the contribution in practice was proposed. The procedure considers the specificity of the method's mathematical model (the assumption that the oil temperature is constant), the non-iterative algorithm's nonlinearity, and the large variations in transformer oil temperature. Existing studies did not consider the significant effect of the oil temperature on the combined measurement uncertainty of partial discharge location influenced by those phenomena. The research is limited to partial discharge located in the transformer oil.

Indexed as

acoustic emissionmeasurement uncertaintymetrologymonte carlo filteringnonlinearitypartial dischargepower transformersoftwaretransformer oil temperature

Identifiers

PMID33809223
PMCPMC7998623

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.