Evidence map›Paper›PMID 33808571›Full record

ArticleSensors (Basel, Switzerland)2021

A Novel Method Based on Headspace-Ion Mobility Spectrometry for the Detection and Discrimination of Different Petroleum Derived Products in Seawater.

Lucas Jaén-González, Ma José Aliaño-González, Marta Ferreiro-González, Gerardo F Barbero, Miguel Palma

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Assessment of Volatile Compound Transference through Firefighter Turnout Gear.International journal of environmental research and public health · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Lucas Jaén-GonzálezDepartment of Analytical Chemistry, Faculty of Sciences, IVAGRO, University of Cadiz, 11510 Cadiz, Spain.
Ma José Aliaño-GonzálezDepartment of Analytical Chemistry, Faculty of Sciences, IVAGRO, University of Cadiz, 11510 Cadiz, Spain.ORCID 0000-0002-5816-4476
Marta Ferreiro-GonzálezDepartment of Analytical Chemistry, Faculty of Sciences, IVAGRO, University of Cadiz, 11510 Cadiz, Spain.ORCID 0000-0003-0870-403X
Gerardo F BarberoDepartment of Analytical Chemistry, Faculty of Sciences, IVAGRO, University of Cadiz, 11510 Cadiz, Spain.ORCID 0000-0001-7302-6605
Miguel PalmaDepartment of Analytical Chemistry, Faculty of Sciences, IVAGRO, University of Cadiz, 11510 Cadiz, Spain.ORCID 0000-0001-8509-4226
Universidad de Cádiz · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of the present study is to develop an optimized method where headspace-ion mobility spectrometry is applied for the detection and discrimination between four petroleum-derived products (PDPs) in water. A Box-Behnken design with a response surface methodology was used, and five variables (incubation temperature, incubation time, agitation, sample volume, and injection volume) with influences on the ion mobility spectrometry (IMS) response were optimized. An IMS detector was used as a multiple sensor device, in which, each drift time acts as a specific sensor. In this way, the total intensity at each drift time is equivalent to multiple sensor signals. According to our results, 2.5 mL of sample incubated for 5 min at 31 °C, agitated at 750 rpm, and with an injection volume of 0.91 mL were the optimal conditions for successful detection and discrimination of the PDPs. The developed method has exhibited good intermediate precision and repeatability with a coefficient of variation lower than 5%, (RSD (Relative Standard Deviation): 2.35% and 3.09%, respectively). Subsequently, the method was applied in the context of the detection and discrimination of petroleum-derived products added to water samples at low concentration levels (2 µL·L

Indexed as

chemometricdetectiondiscriminationIMS sum spectrumion mobility spectrometrypetroleum-derived productsseawatersensorsspills

Identifiers

PMID33808571
PMCPMC8003363
OpenAlexW3137403779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.