Evidence map›Paper›PMID 33808057›Full record

ArticleSensors (Basel, Switzerland)2021

Measurement and Correction of Stooped Posture during Gait Using Wearable Sensors in Patients with Parkinsonism: A Preliminary Study.

Se Hoon Kim, Seo Jung Yun, Quoc Khanh Dang, Youngjoon Chee, Sun Gun Chung, Byung-Mo Oh, Keewon Kim, Han Gil Seo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.2field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Se Hoon KimDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Korea.
Seo Jung YunDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Korea.ORCID 0000-0002-2142-0472
Quoc Khanh DangMKS Instruments Korea, 543 Beonji, Daedeok Techno Valley, Yongsan-dong, Yuseong-gu, Daejeon 34028, Korea.ORCID 0000-0003-1439-0241
Youngjoon CheeSchool of Electrical Engineering, Biomedical Engineering, College of Engineering, University of Ulsan, Ulsan 44610, Korea.
Sun Gun ChungDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Korea.
Byung-Mo OhDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Korea.ORCID 0000-0001-9353-7541
Keewon KimDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Korea.ORCID 0000-0001-6597-578X
Han Gil SeoDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Korea.ORCID 0000-0001-6904-7542
Seoul National University Hospital · KRUniversity of Ulsan · KR

Funding

Korean government (MSIT) NRF-2016M3A9F1941984
6 · The paper itself

Abstract

Stooped posture, which is usually aggravated during walking, is one of the typical postural deformities in patients with parkinsonism. However, the degree of stooped posture is difficult to quantitatively measure during walking. Furthermore, continuous feedback on posture is also difficult to provide. The purpose of this study is to measure the degree of stooped posture during gait and to investigate whether vibration feedback from sensor modules can improve a patient's posture. Parkinsonian patients with stooped posture were recruited for this study. Two wearable sensors with three-axis accelerometers were attached, one at the upper neck and the other just below the C7 spinous process of the patients. After being calibrated in the most upright posture, the sensors continuously recorded the sagittal angles at 20 Hz and averaged the data at every second during a 6 min walk test. In the control session, the patients walked with the sensors as usual. In the vibration session, sensory feedback was provided through vibrations from the neck sensor module when the sagittal angle exceeded a programmable threshold value. Data were collected and analyzed successfully in a total of 10 patients. The neck flexion and back flexion were slightly aggravated during gait, although the average change was <10° in most patients in both measurement sessions. Therefore, it was difficult to evaluate the effect of sensory feedback through vibration. However, some patients showed immediate response to the feedback and corrected their posture during gait. In conclusion, this preliminary study suggests that stooped posture could be quantitatively measured during gait by using wearable sensors in patients with parkinsonism. Sensory feedback through vibration from sensor modules may help in correcting posture during gait in selected patients.

Indexed as

Parkinsonian DisordersWearable Electronic DevicesGaitHumansPostureWalkingbiomechanicsgait/balanceneurologic disordersposture

Identifiers

PMID33808057
PMCPMC8038058
OpenAlexW3145860695

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.