Evidence map›Paper›PMID 33807673›Full record

ArticleBehavioral sciences (Basel, Switzerland)2021

Comparing the Visual Perception According to the Performance Using the Eye-Tracking Technology in High-Fidelity Simulation Settings.

Issam Tanoubi, Mathieu Tourangeau, Komi Sodoké, Roger Perron, Pierre Drolet, Marie-Ève Bélanger, Judy Morris, Caroline Ranger, Marie-Rose Paradis, Arnaud Robitaille and 1 more

Abstract read
In one paragraph

Article in Behavioral sciences (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Issam TanoubiDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.ORCID 0000-0002-6123-0956
Mathieu TourangeauDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.
Komi SodokéCognitive Computing Department, Faculty of Science, University of Quebec at Montreal, Montréal, QC H3C 3P8, Canada.
Roger PerronDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.
Pierre DroletDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.
Marie-Ève BélangerDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.
Judy MorrisDepartment of Emergency Medicine, Faculty of Medicine, Université de Montréal, Montréal, QC H1T 2M4, Canada.
Caroline RangerDepartment of Emergency Medicine, Faculty of Medicine, Université de Montréal, Montréal, QC H1T 2M4, Canada.
Marie-Rose ParadisDepartment of Emergency Medicine, Faculty of Medicine, Université de Montréal, Montréal, QC H1T 2M4, Canada.
Arnaud RobitailleDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.
Mihai GeorgescuDepartment of Anesthesiology, Faculty of Medicine, Montreal, Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Montréal, QC H1T 2M4, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWe used eye-tracking technology to explore the visual perception of clinicians during a high-fidelity simulation scenario. We hypothesized that physicians who were able to successfully manage a critical situation would have a different visual focus compared to those who failed.

methodsA convenience sample of 18 first-year emergency medicine residents were enrolled voluntarily to participate in a high-fidelity scenario involving a patient in shock with a 3rd degree atrioventricular block. Their performance was rated as pass or fail and depended on the proper use of the pacing unit. Participants were wearing pre-calibrated eye-tracking glasses throughout the 9-min scenario and infrared (IR) markers installed in the simulator were used to define various Areas of Interest (AOI). Total View Duration (TVD) and Time to First Fixation (TFF) by the participants were recorded for each AOI and the results were used to produce heat maps.

resultsTwelve residents succeeded while six failed the scenario. The TVD for the AOI containing the pacing unit was significantly shorter (median [quartile]) for those who succeeded compared to the ones who failed (42 [31-52] sec vs. 70 [61-90] sec, DISCUSSION: There seemed to be a connection between the gaze pattern of residents in a high-fidelity bradycardia simulation and their performance. The participants who succeeded looked at the monitor earlier (diagnosis). They also spent less time fixating the pacing unit, using it promptly to address the bradycardia. This study suggests that eye-tracking technology could be used to explore how visual perception, a key information-gathering element, is tied to decision-making and clinical performance.

Indexed as

eye-trackingmedical educationperformance

Identifiers

PMID33807673
PMCPMC7998119

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked