Evidence map›Paper›PMID 33802681›Full record

ArticleSensors (Basel, Switzerland)2021

Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment.

Isis Frausto-Vicencio, Alondra Moreno, Hugh Goldsmith, Ying-Kuang Hsu, Francesca M Hopkins

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Dysprosium Doped Zinc Oxide for NOSensors (Basel, Switzerland) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Isis Frausto-VicencioDepartment of Environmental Sciences, University of California, Riverside, CA 92521, USA.ORCID 0000-0002-2549-7995
Alondra MorenoDepartment of Environmental Sciences, University of California, Riverside, CA 92521, USA.
Hugh GoldsmithSRI Instruments, Torrance, CA 90503, USA.
Ying-Kuang HsuCalifornia Air Resource Board, Sacramento, CA 95814, USA.
Francesca M HopkinsDepartment of Environmental Sciences, University of California, Riverside, CA 92521, USA.
University of California, Riverside · USCalifornia Air Resources Board · US

Funding

California Air Resources Board 17MLD040Medical Scholars Summer Research Program N/ANational Science Foundation 17-123
6 · The paper itself

Abstract

In this study, we test the performance of a compact gas chromatograph with photoionization detector (GC-PID) and optimize the configuration to detect ambient (sub-ppb) levels of benzene, toluene, ethylbenzene, and xylene isomers (BTEX). The GC-PID system was designed to serve as a relatively inexpensive (~10 k USD) and field-deployable air toxic screening tool alternative to conventional benchtop GCs. The instrument uses ambient air as a carrier gas and consists of a Tenax-GR sorbent-based preconcentrator, a gas sample valve, two capillary columns, and a photoionization detector (PID) with a small footprint and low power requirement. The performance of the GC-PID has been evaluated in terms of system linearity and sensitivity in field conditions. The BTEX-GC system demonstrated the capacity to detect BTEX at levels as high as 500 ppb with a linear calibration range of 0-100 ppb. A detection limit lower than 1 ppb was found for all BTEX compounds with a sampling volume of 1 L. No significant drift in the instrument was observed. A time-varying calibration technique was established that requires minimal equipment for field operations and optimizes the sampling procedure for field measurements. With an analysis time of less than 15 min, the compact GC-PID is ideal for field deployment of background and polluted atmospheres for near-real time measurements of BTEX. The results highlight the application of the compact and easily deployable GC-PID for community monitoring and screening of air toxics.

Indexed as

air toxicsbenzeneBTEXgas chromatographytraffic emissions

Identifiers

PMID33802681
PMCPMC8002566
OpenAlexW3129911095

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.