Evidence map›Paper›PMID 33801114›Full record

ArticleSensors (Basel, Switzerland)2021

Noninvasive Flow Monitoring in Simple Flow Phantom Using Resistive Strain Sensors.

Sunghun Jung, Dae Yu Kim

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Recent Progress in Blood Flow Sensing.Sensors and actuators. A, Physical · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sunghun JungDepartment of Electrical Engineering, Inha University, Incheon 22212, Korea.ORCID 0000-0002-1018-710X
Dae Yu KimDepartment of Electrical Engineering, Inha University, Incheon 22212, Korea.

Funding

Inha University Research GrantNational Research Foundation of Korea 2019R1A2C1006814
6 · The paper itself

Abstract

In this paper, we introduce a monitoring method for flow expansion and contraction in a simple flow phantom based on electrical resistance changes in an epidermal strain sensor attached to the phantom. The flow phantom was fabricated to have a nonflat surface and small modulus that are analogous to human skin. The epidermal sensors made of polydopamine and polyvinyl alcohol show sufficient linearity (R = 0.9969), reproducibility, and self-adhesion properties, as well as high sensitivity to small modulus measurements (<1% tensile strain). Pulsatile flow monitoring experiments were performed by placing the epidermal sensor on the flow phantom and measuring the relative changes in resistance by the heartbeat. Experiments were conducted for three types of vessel diameters (1.5, 2, and 3 mm). In each of the experiments, the vessels were divided into Top, Middle, and Bottom positions. Experiments for each position show that the relative changes in resistance increase proportionally with the diameter of the vessel. The vessels located close to the epidermal layer have greater relative electrical changes. The results were analyzed using the Bernoulli equation and hoop stress formula. This study demonstrates the feasibility of a noninvasive flow monitoring method using a novel resistive strain sensor.

Indexed as

flow monitoringflow parametersnoninvasive measurementpulsatile flowstrain sensor

Identifiers

PMID33801114
PMCPMC8004077

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.