Evidence map›Paper›PMID 33800713›Full record

ArticleSensors (Basel, Switzerland)2021

Using a Current Shunt for the Purpose of High-Current Pulse Measurement.

Pawel Piekielny, Andrzej Waindok

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Pawel PiekielnyDepartment of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering, Automatic Control and Informatics, Opole University of Technology, PL-45758 Opole, Poland.ORCID 0000-0002-9961-5982
Andrzej WaindokDepartment of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering, Automatic Control and Informatics, Opole University of Technology, PL-45758 Opole, Poland.ORCID 0000-0002-5921-3583

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measurement of high-current pulses is crucial in some special applications, e.g., electrodynamic accelerators (EA) and converters. In such cases, the current shunts have limitations concerning the frequency bandwidth. To overcome the problem, a method based on the shunt mathematical model is proposed. In the method, the solution of ordinary differential equations for the RL circuit is carried out in order to obtain the real current shape. To check the method, as a referee, a Rogowski coil dedicated to measuring high-current pulses was used. Additionally, the measurement results were compared with the mathematical model of the tested power supply system. Measurements were made for the short power supply circuit, which allows eliminating the nonlinearity. The calculations were carried out using a circuit model. In order to obtain the parameters of the shunt (resistance and inductance), it was modeled using an ANSYS/Q3D Extractor software. Comparison of calculation and measurement results confirms the correctness of our method. In order to compare results, the normalized root mean square error (NRMSE) was used.

Indexed as

circuit modelingcurrent measurementelectrodynamic acceleratorshigh-current pulseshigh-current shuntsRogowski coil

Identifiers

PMID33800713
PMCPMC7961439

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.