Evidence map›Paper›PMID 33797593›Full record

ArticleInternational urogynecology journal2021

Finite element modeling of maximum stress in pelvic floor structures during the head expulsion (FINESSE) study.

Hana Cechova, Vladimir Kalis, Linda Havelkova, Zdenek Rusavy, Pavel Fiala, Martina Rybarova, Ludek Hyncik, Ladislav Krofta, Khaled M Ismail

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in International urogynecology journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Hana CechovaNew Technologies - Research Centre, University of West Bohemia, Pilsen, Czech Republic.
Vladimir KalisDepartment of Obstetrics and Gynecology, University Hospital, Pilsen, Czech Republic.
Linda HavelkovaNew Technologies - Research Centre, University of West Bohemia, Pilsen, Czech Republic.
Zdenek RusavyDepartment of Obstetrics and Gynecology, University Hospital, Pilsen, Czech Republic.
Pavel FialaDepartment of Anatomy, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic.
Martina RybarovaDepartment of Anatomy, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic.
Ludek HyncikNew Technologies - Research Centre, University of West Bohemia, Pilsen, Czech Republic.
Ladislav KroftaInstitute for the Care of Mother and Child, Podolské nábřeží 157, 147 00, Prague, Czech Republic.
Khaled M IsmailDepartment of Obstetrics and Gynecology, Faculty of Medicine, Charles University, alej Svobody 76, 304 60, Pilsen, Czech Republic. khaled.ismail@lfp.cuni.cz.ORCID 0000-0001-9449-0706
Charles University · CZUniversity of West Bohemia in Pilsen · CZÚstav pro Péči o Matku a Dítě · CZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction and hypothesisSeveral studies have assessed birth-related deformations of the levator ani muscle (LAM) and perineum on models that depicted these elements in isolation. The main aim of this study was to develop a complex female pelvic floor computational model using the finite element method to evaluate points and timing of maximum stress at the LAM and perineum in relation to the birth process.

methodsA three-dimensional computational model of the female pelvic floor was created and used to simulate vaginal birth based on data from previously described real-life MRI scans. We developed three models: model A (LAM without perineum); model B (perineum without LAM); model C (a combined model with both structures).

resultsThe maximum stress in the LAM was achieved when the vertex was 9 cm below the ischial spines and measured 37.3 MPa in model A and 88.7 MPa in model C. The maximum stress in the perineum occurred at the time of distension by the suboocipito-frontal diameter and reached 86.7 MPa and 119.6 MPa in models B and C, respectively, while the stress in the posterior fourchette caused by the suboccipito-bregmatic diameter measured 36.9 MPa for model B and 39.8 MPa for model C.

conclusionsIncluding perineal structures in a computational birth model simulation affects the level of stress at the LAM. The maximum stress at the LAM and perineum seems to occur when the head is lower than previously anticipated.

Indexed as

Delivery, ObstetricPelvic FloorDental PorcelainFemaleFinite Element AnalysisHumansPerineumPregnancyDental PorcelainfinesseBirthDeliveryLevatorModelingMusclePartumPerinealStressTension

Identifiers

PMID33797593
OpenAlexW3149744121

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.