Masked Multiplexed Separations to Enhance Duty Cycle for Structures for Lossless Ion Manipulations.

Brian H Clowers, Elvin Cabrera, Gordon Anderson, Liulin Deng, Kelly Moser, Gregory Van Aken, John Daniel DeBord

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Brian H ClowersDepartment of Chemistry, Washington State University, Pullman, Washington 99163, United States.ORCID 0000-0002-5809-9379
Elvin CabreraDepartment of Chemistry, Washington State University, Pullman, Washington 99163, United States.
Gordon AndersonGAA Custom Engineering, Kennewick, Washington 99338, United States.
Liulin DengMOBILion Systems Inc., Chadds Ford, Pennsylvania 19317, United States.ORCID 0000-0002-3692-549X
Kelly MoserMOBILion Systems Inc., Chadds Ford, Pennsylvania 19317, United States.
Gregory Van AkenMOBILion Systems Inc., Chadds Ford, Pennsylvania 19317, United States.
John Daniel DeBordMOBILion Systems Inc., Chadds Ford, Pennsylvania 19317, United States.
Washington State University · US

Funding

Innovative Native Ion Mobility Approaches for Transformational Measurements in Structural BiologyR01GM138863 · NIGMS · TEXAS A&M UNIVERSITY · PI CLOWERS, BRIAN, LAGANOWSKY, ARTHUR D · 2020 to 2023
$1.2M
NIGMS NIH HHS R01 GM138863
6 · The paper itself

Abstract

The experimental paradigm of one ion packet release per spectrum severely hinders throughput in broadband ion mobility spectrometry (IMS) systems (e.g., drift tube and traveling wave systems). Ion trapping marginally mitigates this problem, but the duty cycle deficit is amplified when moving to high resolution, long pathlength systems. As a consequence, new multiplexing strategies that maximize throughput while preserving peak fidelity are essential for high-resolution IMS separations [e.g., structures for lossless ion manipulations (SLIMs) and multi-pass technologies]. Currently, broadly applicable deconvolution strategies for Hadamard-based ion multiplexing are limited to a narrow range of modulation sequences and do not fully maximize the ion signal generated during separation across an extended path length. Compared to prior Hadamard deconvolution errors that rely upon peak picking or discrete error classification, the masked deconvolution matrix technique exploits the knowledge that Hadamard transform artifacts are reflected about the central, primary signal [i.e., the true arrival time distribution (ATD)]. By randomly inducing mathematical artifacts, it is possible to identify spectral artifacts simply by their high degree of variability relative to the core ATD. It is important to note that the deweighting approach using the masked deconvolution matrix does not make any assumptions about the underlying transform and is applicable to any multiplexing strategy employing binary sequences. In addition to demonstrating a 100-fold increase in the total number of ions detected, the effective deconvolution of data from 5, 6, 7, and 8-bit pseudo-random sequences expands the utility and efficiency of the SLIM platform.