Evidence map›Paper›PMID 33795781›Full record

ArticleScientific reports2021

Biosafety and efficacy evaluation of a biodegradable magnesium-based drug-eluting stent in porcine coronary artery.

Jinzhou Zhu, Xiyuan Zhang, Jialin Niu, Yongjuan Shi, Zhengbin Zhu, Daopeng Dai, Chenxin Chen, Jia Pei, Guangyin Yuan, Ruiyan Zhang

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 37 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Progress in research and development of biodegradable metallic vascular stents.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2024
    Review
  9. Article
  10. Research progress of absorbable stents.International journal of medical sciences · 2024
    Review
  11. Review
  12. Review
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Jinzhou Zhu *Department of Cardiology, RuiJin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 20025, People's Republic of China.
Xiyuan Zhang *National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
Jialin Niu *National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
Yongjuan ShiNational Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
Zhengbin ZhuDepartment of Cardiology, RuiJin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 20025, People's Republic of China.
Daopeng DaiDepartment of Cardiology, RuiJin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 20025, People's Republic of China.
Chenxin ChenNational Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
Jia PeiNational Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
Guangyin YuanNational Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China. gyyuan@sjtu.edu.cn.
Ruiyan ZhangDepartment of Cardiology, RuiJin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 20025, People's Republic of China. rjzhangruiyan@aliyun.com.
Shanghai Jiao Tong University · CNRuijin Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although the drug-eluting stent (DES) has become the standard for percutaneous coronary intervention (PCI)-based revascularization, concerns remain regarding the use of DES, mainly due to its permanent rigid constraint to vessels. A drug-eluting bioresorbable stent (BRS) was thus developed as an alternative to DES, which can be absorbed entirely after its therapeutic period. Magnesium (Mg)-based BRSs have attracted a great deal of attention due to their suitable mechanical properties, innovative chemical features, and well-proven biocompatibility. However, the primary disadvantage of Mg-based BRSs is the rapid degradation rate, resulting in the early loss of structural support long before the recovery of vascular function. Recently, a new type of patented Mg-Nd-Zn-Zr alloy (JDBM) was developed at Shanghai Jiao Tong University to reduce the degradation rate compared to commercial Mg alloys. In the present investigation, a poly(D,L-lactic acid)-coated and rapamycin eluting (PDLLA/RAPA) JDBM BRS was prepared, and its biosafety and efficacy for coronary artery stenosis were evaluated via in vitro and in vivo experiments. The degree of smooth muscle cell adhesion to the PDLLA/RAPA coated alloy and the rapamycin pharmacokinetics of JDBM BRS were first assessed in vitro. JDBM BRS and commercial DES FIREHAWK were then implanted in the coronary arteries of a porcine model. Neointimal hyperplasia was evaluated at 30, 90, and 180 days, and re-endothelialization was evaluated at 30 days. Furthermore, Micro-CT and optical coherence tomography (OCT) analyses were performed 180 days after stent implantation to evaluate the technical feasibility, biocompatibility, and degradation characteristics of JDBM BRS in vivo. The results show the ability of a PDLLA/RAPA coated JDBM to inhibit smooth muscle cell adhesion and moderate the drug release rate of JDBM BRS in vitro. In vivo, low local and systemic risks of JDBM BRS were demonstrated in the porcine model, with preserved mechanical integrity after 6 months of implantation. We also showed that this novel BRS was associated with a similar efficacy profile compared with standard DES and high anti-restenosis performance. These findings may confer long term advantages for using this BRS over a traditional DES.

Indexed as

Drug-Eluting StentsAlloysAnimalsAorta, ThoracicCell AdhesionContainment of BiohazardsCoronary AngiographyCoronary RestenosisCoronary VesselsMagnesiumMicroscopy, Electron, ScanningMyocytes, Smooth MuscleNeodymiumPatient SafetyPercutaneous Coronary InterventionPolyestersAlloysMagnesiumNeodymiumPolyesterspoly(lactide)SirolimusZincZirconium

Identifiers

PMID33795781
PMCPMC8016955
OpenAlexW3110458864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.