Evidence map›Paper›PMID 33795675›Full record

ArticleNature communications2021

Axial localization and tracking of self-interference nanoparticles by lateral point spread functions.

Yongtao Liu, Zhiguang Zhou, Fan Wang, Günter Kewes, Shihui Wen, Sven Burger, Majid Ebrahimi Wakiani, Peng Xi, Jiong Yang, Xusan Yang and 2 more

Abstract read
In one paragraph

Article in Nature communications, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Yongtao Liu *Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.ORCID 0000-0003-0241-7718
Zhiguang Zhou *Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.ORCID 0000-0002-9648-1325
Fan Wang *Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia. fan.wang@uts.edu.au.ORCID 0000-0001-7403-3305
Günter KewesAG Nanooptik, Institut für Physik & IRIS Adlershof, Humboldt Universität zu Berlin, Newtonstraße 15, 12489, Berlin, Germany.
Shihui WenInstitute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.ORCID 0000-0002-4670-4658
Sven BurgerJCMwave GmbH, Bolivarallee 22, 14050, Berlin, Germany.ORCID 0000-0002-3140-5380
Majid Ebrahimi WakianiInstitute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.
Peng XiInstitute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.
Jiong YangInstitute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.
Xusan YangDepartment of Biomedical Engineering, College of Engineering, Peking University, Beijing, 100871, China.ORCID 0000-0001-8429-6299
Oliver BensonAG Nanooptik, Institut für Physik & IRIS Adlershof, Humboldt Universität zu Berlin, Newtonstraße 15, 12489, Berlin, Germany. oliver.benson@physik.hu-berlin.de.
Dayong JinInstitute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia. dayong.jin@uts.edu.au.ORCID 0000-0003-1046-2666

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Sub-diffraction limited localization of fluorescent emitters is a key goal of microscopy imaging. Here, we report that single upconversion nanoparticles, containing multiple emission centres with random orientations, can generate a series of unique, bright and position-sensitive patterns in the spatial domain when placed on top of a mirror. Supported by our numerical simulation, we attribute this effect to the sum of each single emitter's interference with its own mirror image. As a result, this configuration generates a series of sophisticated far-field point spread functions (PSFs), e.g. in Gaussian, doughnut and archery target shapes, strongly dependent on the phase difference between the emitter and its image. In this way, the axial locations of nanoparticles are transferred into far-field patterns. We demonstrate a real-time distance sensing technology with a localization accuracy of 2.8 nm, according to the atomic force microscope (AFM) characterization values, smaller than 1/350 of the excitation wavelength.

Identifiers

PMID33795675
PMCPMC8016974

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.