Evidence map›Paper›PMID 33793622›Full record

ArticlePloS one2021

Fracture strength analysis of titanium insert-reinforced zirconia abutments according to the axial height of the titanium insert with an internal connection.

Seung-Rye Song, Kyeong-Mee Park, Bock-Young Jung

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Seung-Rye SongDepartment of Advanced General Dentistry, Dankook University College of Dentistry, Cheonan, Korea.
Kyeong-Mee ParkDepartment of Advanced General Dentistry, Human Identification Research Institute, Yonsei University College of Dentistry, Seoul, Korea.
Bock-Young JungDepartment of Advanced General Dentistry, Yonsei University College of Dentistry, Seoul, Korea.ORCID 0000-0002-8186-2109

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to analyze fracture strength in vitro by varying the axial height of the titanium insert and the labial height of the zirconia abutment in an internal connection implant to identify the titanium insert axial height with optimal mechanical stability. Sixty implants with an internal connection system were used. Two-piece zirconia abutments were used with the titanium inserts. Combinations of different titanium insert axial heights (mm) and zirconia abutment labial heights (mm) constituted five groups: Gr1 (1-3), Gr2 (3-3), Gr3 (3-5), Gr4 (5-3), and Gr5 (5-5). After thermocycling, a fracture load test was performed with a universal testing machine. The initial deformation load and the fracture load were measured and analyzed. The fractured surface and cross-section of the specimens were examined by scanning electron microscopy (SEM). The groups of titanium inserts with axial heights of 3 mm and 5 mm showed significantly greater initial deformation load and fracture load than the group with an axial height of 1 mm (p < 0.05), but there was no significant difference between the two groups with axial heights of 3 mm and 5 mm. The labial height of the zirconia abutment had no significant influence on the initial deformation load and fracture load. In some specimens in Gr4 and Gr5, cracking or bending of the titanium insert and abutment screw was observed on SEM. The axial height of the titanium insert should be designed to not be less than 3 mm to increase the fracture strength and promote the long-term stability of implants.

Indexed as

Stress, MechanicalDental AbutmentsDental Restoration FailureDental Stress AnalysisFlexural StrengthFractures, BoneHumansMaterials TestingMicroscopy, Electron, ScanningTitaniumZirconiumTitaniumZirconiumzirconium oxide

Identifiers

PMID33793622
PMCPMC8016344

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.