Transcoronary pacing in an animal model : Second coated guidewire versus cutaneous patch as indifferent electrodes.

Konstantin M Heinroth, Susanne Unverzagt, Dirk Mahnkopf, Charlotte Horenburg, Hannes Melnyk, Daniel Sedding, Roland Prondzinsky

Abstract read
PubMed Publisher
In one paragraph

Article in Medizinische Klinik, Intensivmedizin und Notfallmedizin, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Konstantin M HeinrothDepartment of Medicine III, Martin-Luther-University Halle-Wittenberg, Ernst-Grube-Straße 40, 06120, Halle, Germany. konstantin.heinroth@uk-halle.de.ORCID http://orcid.org/0000-0003-3279-7379
Susanne UnverzagtMartin-Luther-University Halle-Wittenberg, Institute of General Practice and Family Medicine, Halle/Saale, Germany.
Dirk MahnkopfIMTR GmbH, Rottmersleben, Germany.
Charlotte HorenburgDepartment of Medicine III, Martin-Luther-University Halle-Wittenberg, Ernst-Grube-Straße 40, 06120, Halle, Germany.
Hannes MelnykDepartment of Medicine III, Martin-Luther-University Halle-Wittenberg, Ernst-Grube-Straße 40, 06120, Halle, Germany.
Daniel SeddingDepartment of Medicine III, Martin-Luther-University Halle-Wittenberg, Ernst-Grube-Straße 40, 06120, Halle, Germany.
Roland ProndzinskyDepartment of Medicine I, Klinikum Merseburg, Merseburg, Germany.
Martin Luther University Halle-Wittenberg · DEMerseburg University of Applied Sciences · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTranscoronary pacing is a seldom used treatment option for unheralded bradycardias in the setting of percutaneous coronary interventions (PCI). In the present study we compared a coated guidewire inserted proximally into a coronary artery with a cutaneous patch electrode as indifferent electrodes for transcoronary pacing in a porcine model.

methodsTranscoronary pacing was investigated in 7 adult pigs in an animal catheterization laboratory. A standard guidewire insulated by a monorail-balloon was advanced into the periphery of a coronary artery serving as the cathode. As the indifferent anode, a special guidewire with electrical insulated by a polytetrafluoroethylene (PTFE) coating was positioned into the proximal part of the same coronary vessel. Transcoronary pacing parameters (threshold and impedance data and the magnitude of the epicardial electrogram) were compared with unipolar transcoronary pacing using a cutaneous patch electrode.

resultsTranscoronary pacing was successful against both indifferent electrodes. Pacing thresholds obtained with the coated guidewire technique (1.8 ± 1.3 V) were similar to those obtained by standard unipolar transcoronary pacing with a cutaneous patch electrode (1.8 ± 1.5 V). The impedance with the additional coated guidewire was 419 ± 144 Ω and thereby slightly higher compared to 320 ± 103 Ω obtained by pacing against the patch electrode (p < 0.05). Both settings yielded comparable R‑wave amplitudes (8.0 ± 5.1 mV vs. 7.1 ± 3.6 mV).

conclusionsA second coated guidewire is as effective as a cutaneous patch electrode when added as an indifferent electrode in transcoronary pacing. This transcoronary pacing technique could replace temporary transvenous pacing in emergency situations during PCI, especially when using the radial approach.

Indexed as

Percutaneous Coronary InterventionAnimalsCardiac Pacing, ArtificialCatheterizationElectrodesHumansModels, AnimalSwineBradycardiaCoated guidewireCutaneous patch electrodePercutaneous coronary interventionsTemporary transcoronary pacing

Identifiers

PMID33787979
OpenAlexW3139865751

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.