Evidence map›Paper›PMID 33786810›Full record

SynthesisThe Cochrane database of systematic reviews2021

Circumcision devices versus standard surgical techniques in adolescent and adult male circumcisions.

Ameer Hohlfeld, Sumayyah Ebrahim, Muhammed Zaki Shaik, Tamara Kredo

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it, 23 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Ameer HohlfeldCochrane South Africa, South African Medical Research Council, Cape Town, South Africa.
Sumayyah EbrahimSchool of Clinical Medicine, Department of Surgery, University of KwaZulu-Natal, Durban, South Africa.
Muhammed Zaki ShaikSchool of Clinical Medicine, Department of Surgery, University of KwaZulu-Natal, Durban, South Africa.
Tamara KredoCochrane South Africa, South African Medical Research Council, Cape Town, South Africa.
South African Medical Research Council · ZAUniversity of KwaZulu-Natal · ZA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMedical circumcisions are among the most common surgical procedures performed in males. The usual indications are phimosis (inability to completely retract the foreskin and expose the glans due to a congenital or acquired constriction of the prepuce), paraphimosis (when the foreskin is not pulled back over the glans after retraction resulting in a tight constricting band which causes swelling of the distal penis and acute discomfort), balanoposthitis (erythema and edema of the prepuce and glans) and balanitis (inflammation is confined to the glans; the foreskin is usually non-retractile). Circumcision devices have been developed to shorten the operative time, simplify techniques, and improve safety and cosmetic outcomes. The devices generally aim to crush the foreskin while simultaneously creating hemostasis, the foreskin is then excised or allowed to slough off. Their use is supposedly safer and easier to replicate than the standard dissection techniques. There are at least 20 devices for male circumcision on the market, yet their effectiveness has not been reviewed to date.

objectivesTo assess the effects of device-based circumcisions compared with standard surgical techniques in adolescent and adult males (10 years old and above). SEARCH

methodsWe performed a comprehensive search with no restrictions to the language of publication or publication status. We searched the Cochrane Library, MEDLINE (PubMed), Embase, Web of Science, trials registries, grey literature sources and conference proceedings up to 16 April 2020. SELECTION CRITERIA: We included randomized controlled trials of device-based circumcisions (crush or ligature circumcision devices) compared to standard surgical dissection-based circumcision conducted by health professionals in a medical setting. DATA COLLECTION AND ANALYSIS: At least two review authors independently assessed study eligibility and extracted data from the included studies. We classified adverse events into serious, moderate or mild. We reported study results as risk ratios (RR) or mean differences (MD) using 95% confidence intervals (CI) and a random-effects model. We used the GRADE approach to evaluate the overall certainty of the evidence for each outcome. MAIN

resultsEighteen trials met the inclusion criteria. Trials were conducted in China, South Africa, Kenya and Zambia, Mozambique, Rwanda, Uganda and Zimbabwe. Primary outcomes Serious adverse events: there were no serious adverse events in either treatment arm (11 trials, 3472 participants). Moderate adverse events: there may be a slight increase in moderate adverse events when devices are used compared to standard surgical techniques (RR 1.31, 95% CI 0.55 to 3.10; I²= 68%; 10 trials, 3370 participants; low-certainty evidence); this corresponds to 8 more (ranging from 15 fewer to 84 more) moderate adverse events per 1000 participants. We downgraded the certainty of the evidence for study limitations and imprecision. Secondary outcomes Mild adverse events: we are uncertain about the difference in mild adverse events between groups when devices are used compared to standard surgical techniques (RR 1.09, 95% CI 0.44 to 2.72; I² = 91%; 10 trials, 3370 participants; very low-certainty evidence). We downgraded the certainty of the evidence for study limitations, imprecision and unexplained inconsistency. Operative time: operative time is probably about 17 minutes shorter when using a device rather than standard surgical techniques, which constitutes a clinically meaningful decrease in a procedure (MD -17.26 minutes, 95% CI -19.96 to -14.57; I² = 99%; 14 trials, 4812 participants; moderate-certainty evidence). We downgraded the certainty of the evidence for serious study limitations. The standard surgical technique generally takes about 24 minutes. There may be less postoperative pain during the first 24 hours when circumcision devices are used compared to standard surgical techniques (measured using a visual analog scale [VAS]; MD 1.30 cm lower, 95% CI 2.37 lower to 0.22 lower; I² = 99%; 9 trials, 3022 participants; low-certainty evidence). We downgraded the certainty of the evidence for study limitations and unexplained heterogeneity. There may be little or no difference in postoperative pain experienced during the first seven days when compared with standard surgical techniques (measured using a VAS; MD 0.11 cm higher, 95% CI 0.89 lower to 1.11 higher; I² = 94%; 4 trials, 1430 participants; low-certainty evidence). We downgraded the certainty of the evidence for study limitations and unexplained inconsistency. A higher score on the VAS indicates greater pain. Participants may slightly prefer circumcision devices compared to standard surgical techniques (RR 1.19, 95% CI 1.04 to 1.37; I² = 97%; 15 trials, 4501 participants; low-certainty evidence). We downgraded the certainty of the evidence for study limitations and unexplained inconsistency. We recorded satisfaction as a dichotomous outcome. Higher rates reflected greater satisfaction. AUTHORS'

conclusionsWe found that there were no serious adverse events reported when using a circumcision device compared to standard surgical techniques, but they may slightly increase moderate adverse effects, and it is unclear whether there is a difference in mild adverse effects. Use of circumcision devices probably reduces the time of the procedure by about 17 minutes, a clinically meaningful time saving. For patients, use of the circumcision device may result in lower pain scores during the first 24 hours and patients may be slightly more satisfied with it compared with standard surgical techniques. Clinicians, patients and policymakers can use these results in conjunction with their own contextual factors to inform the approach that best suits their healthcare settings. High-quality trials evaluating this intervention are needed to provide further certainty regarding the rates of adverse effects and postoperative pain of using devices compared to standard approaches.

Indexed as

AdolescentAdultBiasChildCircumcision, MaleHumansMaleMiddle AgedOperative TimePatient PreferencePostoperative PainRandomized Controlled Trials as TopicYoung Adult

Identifiers

PMID33786810
PMCPMC8095026
OpenAlexW2762765339

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.