SynthesisESC heart failure2021
Effect of Carillon Mitral Contour System on patient-reported outcomes in functional mitral regurgitation: an individual participant data meta-analysis.
Synthesis in ESC heart failure, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.
- Effect of Carillon Mitral Contour System on patient-reported outcomes in functional mitral regurgitation: an individual participant data meta-analysis.ESC heart failure · 2021Pooled it
- Results of the Carillon Procedure in Proportionate and Disproportionate FMR: Effects of the Baseline Echocardiographic Parameters.Journal of clinical medicine · 2026Article
- The Carillon device in the treatment of patients with functional mitral regurgitation.Future cardiology · 2026Review
- Technologies in minimally invasive treatment of severe mitral regurgitation.Cardiology journal · 2026Review
- The evolution of technical prerequisites and local boundary conditions for optimization of mitral valve interventions-Emphasis on skills development and institutional risk performance.Frontiers in cardiovascular medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsThe Carillon Mitral Contour System has been shown to reduce mitral regurgitation and left ventricular volumes in symptomatic heart failure patients with functional mitral regurgitation. We sought to evaluate the effects of the Carillon device on quality of life and functional capacity in these patients. METHODS AND
resultsAn individual participant data meta-analysis was conducted utilizing data from REDUCE-FMR, TITAN, and TITAN II studies. The main outcomes assessed were changes from baseline in Kansas City Cardiomyopathy Questionnaire overall summary scores (KCCQ-OSS), 6 min walk test (6MWT) distance, and New York Heart Association (NYHA) classification at Months 1 and 12 after device implantation. Subgroup analyses were conducted for patients with severe functional mitral regurgitation (Grade 3 or 4). Pooled estimates were calculated using a random-effects model and are presented as weighted proportions or weighted mean differences along with 95% confidence intervals (CIs). Among 139 patients included in the analysis, Carillon device significantly improved the 6MWT distance (63.0 m; 95% CI 18.8-107.2, P = 0.0056) and KCCQ-OSS score (15.1; 95% CI 5.6-24.7, P = 0.0022) at 1 month from baseline. These benefits were sustained at 12 months (64.1 m; 95% CI 13.2-115.0, P = 0.0141, for 6MWT distance, and 12.3; 95% CI 4.7-19.8, P = 0.0019, for KCCQ-OSS score). More than 50% of the patients had improvements in KCCQ-OSS by ≥5 (60.4%; 95% CI 47.4-72.1) and 10 points (50.5%; 95% CI 34.9-66.0) at 12 months. Almost half of the patients experienced a ≥1 class improvement in NYHA class after implantation of the device at 1 month (67.9%; 95% CI 37.3-88.3) and at 12 months (48.8%; 95% CI 31.8-66.2). Results remained similar for KCCQ-OSS, 6MWT distance, and NYHA classification when only patients with Grade 3 or 4 mitral regurgitation were analysed. The pooled estimates of 30 day and 1 year all-cause mortality were 2.2% (95% CI 0.7-6.5) and 17.3% (95% CI 11.8-24.5), respectively.
conclusionsThe Carillon Mitral Contour System significantly improved patient-reported quality-of-life outcomes in heart failure patients with functional mitral regurgitation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials