Evidence map›Paper›PMID 33777586›Full record

ArticleCureus2021

Successful Percutaneous Closure of a Large Saphenous Vein Graft Aneurysm With Vascular Plug 4, Optimal Percutaneous Device Selection.

Kazuyuki Ishibashi, Mamika Motokawa, Noboru Motomura

Open access · diamondAbstract readCase Reports
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Kazuyuki IshibashiCardiovascular Surgery, Toho University Sakura Medical Center, Sakura, JPN.
Mamika MotokawaCardiovascular Surgery, Goi Hospital, Ichihara, JPN.
Noboru MotomuraCardiovascular Surgery, Toho University Sakura Medical Center, Sakura, JPN.
Toho University Medical Center Sakura Hospital · JPToho University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Saphenous vein graft (SVG) aneurysm is one of the late unusual complications of coronary artery bypass grafting (CABG). We report a case of a very large SVG aneurysm successfully treated with a vascular plug 4. A 94-year-old man was referred to our hospital for an expanding aortic aneurysm. The patient had undergone CABG 24 years prior, with three SVGs to the left anterior descending (LAD) artery, left circumflex arteries (LCX) artery, and right coronary artery (RCA). A computed tomography scan of the chest demonstrated an 8.8 cm × 6.5 cm aneurysm arising from an ascending aortic wall. Coronary angiography revealed an aneurysm arising from the proximal segment of the SVG to the RCA. The distal graft anastomosis of the SVG to the RCA and LCX was occluded. Another SVG to the LAD was widely patent. From a radial approach, a 5-Fr catheter (Tempo, Cardinal Health, OH) was advanced into its cavity, and a 7-mm Amplatzer vascular plug 4 (AVP-IV, AGA Medical Corporation, MN) was successfully delivered. Contrast CT confirmed a thrombus development in the cavity. The patient was discharged home. However, interventions utilizing vascular plug insertion are limited to cases of graft occlusion. We report a case of the successful treatment of a large SVG aneurysm using the Amplatzer vascular plug 4.

Indexed as

aneurysmcoronary artery bypass grafting(cabg)vein graft

Identifiers

PMID33777586
PMCPMC7984959
OpenAlexW3138608882

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked