Evidence map›Paper›PMID 33776191›Full record

ArticleApplied energy2021

A fresh (air) look at ventilation for COVID-19: Estimating the global energy savings potential of coupling natural ventilation with novel radiant cooling strategies.

Dorit Aviv, Kian Wee Chen, Eric Teitelbaum, Denon Sheppard, Jovan Pantelic, Adam Rysanek, Forrest Meggers

Open access · greenAbstract read
In one paragraph

Article in Applied energy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
12.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 105 citations in OpenAlex.

  1. Article
  2. Level of Patient Satisfaction with Quality of Primary Healthcare in Almaty During COVID-19 Pandemic.International journal of environmental research and public health · 2025
    Article
  3. The potential importance of the built-environment microbiome and its impact on human health.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. A critical review of heating, ventilation, and air conditioning (HVAC) systems within the context of a global SARS-CoV-2 epidemic.Process safety and environmental protection : transactions of the Institution of Chemical Engineers, Part B · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Dorit AvivUniversity of Pennsylvania, Philadelphia, PA, USA.
Kian Wee ChenPrinceton University, Princeton, NJ, USA.
Eric TeitelbaumPrinceton University, Princeton, NJ, USA.
Denon SheppardUniversity of British Columbia, Vancouver, BC, Canada.
Jovan PantelicUniversity of California, Berkeley, CA, USA.
Adam RysanekUniversity of British Columbia, Vancouver, BC, Canada.
Forrest MeggersPrinceton University, Princeton, NJ, USA.
Princeton University · USUniversity of British Columbia · CAKU Leuven · BEUniversity of Pennsylvania · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Radiant cooling-assisted natural ventilation is an innovative technical approach that combines new radiant cooling technology with natural ventilation to increase fresh air delivery into buildings year-round with minimal energy cost and improvment of air quality. Currently, the standard paradigm for HVAC (heating, ventilation and air conditioning) is based on central air systems that tie the delivery of heating and cooling to the delivery of fresh air. To prevent heat loss, the delivery of fresh air must be tightly controlled and is often limited through recirculation of already heated or cooled air. Buildings are designed with airtight envelopes, which do not allow for natural ventilation, and depend on energy-intensive central-air systems. As closed environments, buildings have become sites of rapid COVID-19 transmission. In this research, we demonstrate the energy cost of increasing outdoor air supply with standard systems per COVID-19 recommendations and introduce an alternative HVAC paradigm that maximizes the decoupling of ventilation and thermal control. We first consider a novel analysis of the energy costs of increasing the amount of conditioned fresh air using standard HVAC systems to address COVID-19 concerns. We then present an alternative that includes a novel membrane-assisted radiant system we have studied for cooling in humid climates, in place of an air conditioning system. The proposed system can work in conjunction with natural ventilation and thus decreases the risk of indoor spread of infectious diseases and significantly lowers energy consumption in buildings. Our results for modeling HVAC energy in different climates show that increasing outdoor air in standard systems can double cooling costs, while increasing natural ventilation with radiant systems can halve costs. More specifically, it is possible to add up to 100 days' worth of natural ventilation while saving energy when coupling natural ventilation and radiant systems. This combination decreases energy costs by 10-45% in 60 major cities globally, while increasing fresh air intake.

Indexed as

Air qualityCOVID-19Energy costNatural ventilationRadiant systemsThermal comfort