Observational studyDiabetologia2021
Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls.
Observational study in Diabetologia, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06130215 (Evaluation on Glycemic Control Using Two Different Meal Announcement Plans in Adolescents With Type 1 Diabetes on Minimed 780G Hybrid Closed Loop System), which is not on this map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evaluation on Glycemic Control Using Two Different Meal Announcement Plans in Adolescents With Type 1 Diabetes on Minimed 780G Hybrid Closed Loop System
Who cites it
29 citing papers in PubMed, 57 citations in OpenAlex.
- A Nurse-Led Educational Intervention for Patients With Type 1 Diabetes Using Continuous Glucose Monitoring.Worldviews on evidence-based nursing · 2026Trial
- Flash glucose monitoring in gestational diabetes mellitus (FLAMINGO): a randomised controlled trial.Acta diabetologica · 2023Trial
- Trial
- Continuous Glucose Monitoring Metrics and Risks of Severe Hypoglycemia and Diabetic Ketoacidosis in Type 1 Diabetes: A Pooled Analysis.Diabetes care · 2026Article
- Continuous Glucose Monitoring Intervention for Hispanic Adults With Type 1 Diabetes Receiving Care in a Federally Qualified Health Center: Protocol for a Mixed Methods, Pragmatic Pilot Randomized Controlled Trial.JMIR research protocols · 2026Article
- A Hybrid Closed-Loop Blood Glucose Control Algorithm with a Safety Limiter Based on Deep Reinforcement Learning and Model Predictive Control.Biosensors · 2026Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2026.Diabetes care · 2026Review
- Cost-Utility Analysis of FreeStyle Libre Systems in People with Type 2 Diabetes Mellitus on Treatment with Basal Insulin and Poor Glycemic Control in Spain.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2026Article
- Double-Layer Simplified Complex Interval Neural Network Stacking for Blood Glucose Prediction of Continuous Glucose Monitoring System.Biosensors · 2025Article
- Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2025.Diabetes care · 2025Review
- Population-Based Study on the Implementation of Flash Glucose Monitoring and Severe Hypoglycemia in Adults With Type 1 Diabetes.Diabetes technology & therapeutics · 2024Article
- Disparities in Diabetes Technology Uptake in Youth and Young Adults With Type 1 Diabetes: A Global Perspective.Journal of the Endocrine Society · 2024Review
- The Efficacy and Acceptability of Flash Glucose Monitoring in Pregnant Women with Gestational Diabetes Mellitus: A Systematic Review.Journal of clinical medicine · 2024Review
- Japanese candlestick charts for diabetes.World journal of methodology · 2024Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2024.Diabetes care · 2024Review
- Real-world glycaemic outcomes in patients with type 1 diabetes using glucose sensors-Experience from a single centre in Dublin.Endocrinology, diabetes & metabolism · 2024Article
- An mHealth Text Messaging Program Providing Symptom Detection Training and Psychoeducation to Improve Hypoglycemia Self-Management: Intervention Development Study.JMIR formative research · 2023Article
- Spanish Consensus on the Use of Intermittently Scanned Continuous Glucose Monitoring in the Management of Patients With Insulin Therapy: The MONITOR Project.Journal of diabetes science and technology · 2023Article
- Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes.Endocrine connections · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aims/hypothesisThe aim of this work was to evaluate changes in glycaemic control (HbA
methodsUsing data from the Swedish National Diabetes Registry, 14,372 adults with type 1 diabetes with a new registration of FM during 2016-2017 and with continued FM for two consecutive years thereafter, and 7691 control individuals using conventional self-monitoring of blood glucose (SMBG) during the same observation period, were included in a cohort study. Propensity sores and inverse probability of treatment weighting (IPTW) were used to balance FM users with SMBG users. Changes in HbA
resultsAfter the start of FM, the difference in IPTW change in HbA CONCLUSIONS/
interpretationIn this large cohort, the use of FM was associated with a small and sustained improvement in HbA
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.