Evidence map›Paper›PMID 33772376›Full record

ArticleMikrochimica acta2021

Laser engraved microapillary pump paper-based microfluidic device for colorimetric and electrochemical detection of salivary thiocyanate.

Kingkan Pungjunun, Abdulhadee Yakoh, Sudkate Chaiyo, Narong Praphairaksit, Weena Siangproh, Kurt Kalcher, Orawon Chailapakul

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 41 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Kingkan PungjununElectrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
Abdulhadee YakohElectrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
Sudkate ChaiyoElectrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
Narong PraphairaksitElectrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
Weena SiangprohDepartment of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand.
Kurt KalcherInstitute of Chemistry, Karl-Franzens University, Universitätsplatz 1, A-8010, Graz, Austria.
Orawon ChailapakulElectrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand. corawon@chula.ac.th.
Chulalongkorn University · THSrinakharinwirot University · THUniversity of Graz · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A microcapillary grooved paper-based analytical device capable of dual-mode sensing (colorimetric and electrochemical detection) was demonstrated for analysis of viscous samples (e.g., human saliva). Herein, a hollow capillary channel was constructed via laser engraved micropatterning functions as a micropump to facilitate viscous fluidic transport, which would otherwise impede analysis on paper devices. Using salivary thiocyanate as a model analyte, the proposed device was found to exhibit a promising sensing ability on paper devices without the need for sample pretreatment or bulky instrumentation, as normally required in conventional methods used for saliva analysis. An extensive linear dynamic range covering detection of salivary thiocyanate for both high and trace level regimes (5 orders of magnitude working range) was collectively achieved using the dual-sensing modes. Under optimal conditions, the limit of detection was 6 μmol L

Indexed as

Lab-On-A-Chip DevicesPaperColorimetryElectrochemical TechniquesElectrodesGraphiteHumansIndolesLasersLimit of DetectionMicrofluidic Analytical TechniquesNon-SmokersOrganometallic CompoundsSalivaSmokersThiocyanatescopper phthalocyanineGraphiteIndolesOrganometallic CompoundsthiocyanateThiocyanatesColorimetric detectionElectrochemical detectionMicrofluidic devicePaper-based analytical deviceSensors

Identifiers

PMID33772376
OpenAlexW3138627606

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.