Evidence map›Paper›PMID 33768465›Full record

ArticleMolecular imaging and biology2021

Performance Evaluation of SimPET-X, a PET Insert for Simultaneous Mouse Total-Body PET/MR Imaging.

Kyeong Yun Kim, Jeong-Whan Son, Kyuwan Kim, Yina Chung, Ji Yong Park, Yun-Sang Lee, Guen Bae Ko, Jae Sung Lee

Abstract read
PubMed Publisher
In one paragraph

Article in Molecular imaging and biology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. [Advances in multimodal biomedical imaging of small animals].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
  3. Article
  4. Submillimeter-Resolution PET for High-Sensitivity Mouse Brain Imaging.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023
    Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 3 countries.

Kyeong Yun KimDepartment of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Korea.
Jeong-Whan SonBrightonix Imaging Inc., #1705, Seongsu-yeok SK V1 Tower, 25, Yeonmujang 5ga-gil, Seongdong-gu, Seoul, 04782, Korea.
Kyuwan KimBrightonix Imaging Inc., #1705, Seongsu-yeok SK V1 Tower, 25, Yeonmujang 5ga-gil, Seongdong-gu, Seoul, 04782, Korea.
Yina ChungBrightonix Imaging Inc., #1705, Seongsu-yeok SK V1 Tower, 25, Yeonmujang 5ga-gil, Seongdong-gu, Seoul, 04782, Korea.
Ji Yong ParkDepartment of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Korea.
Yun-Sang LeeInstitute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, Korea.
Guen Bae KoBrightonix Imaging Inc., #1705, Seongsu-yeok SK V1 Tower, 25, Yeonmujang 5ga-gil, Seongdong-gu, Seoul, 04782, Korea. guenbko@gmail.com.
Jae Sung LeeDepartment of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Korea. jaes@snu.ac.kr.ORCID 0000-0001-7623-053X
Seoul National University · KRSK Group (South Korea) · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn this study, a small animal PET insert (SimPET-X, Brightonix Imaging Inc.) for simultaneous PET/MR imaging studies is presented. This insert covers an 11-cm-long axial field-of-view (FOV) and enables imaging of mouse total-bodies and rat heads. PROCEDURES: SimPET-X comprises 16 detector modules to yield a ring diameter of 63 mm and an axial FOV of 110 mm. The detector module supports four detector blocks, each comprising two 4 × 4 SiPM arrays coupled with a 20 × 9 array of LSO crystals (1.2 × 1.2 × 10 mm

resultsThe radial spatial resolutions at the center based on 3D OSEM without and with the warm background were 0.73 mm and 0.99 mm, respectively. The absolute peak sensitivity of the system was 10.44% with an energy window of 100-900 keV and 8.27% with an energy window of 250-750 keV. The peak NECR and scatter fraction for the mouse phantom were 348 kcps at 26.2 MBq and 22.1% with an energy window of 250-750 keV, respectively. The standard deviation of pixel value in the uniform region of an NEMA IQ phantom was 4.57%. The spillover ratios for air- and water-filled chambers were 9.0% and 11.0%, respectively. In the hot-rod phantom image reconstructed using 3D OSEM-PSF, all small rods were resolved owing to the high spatial resolution of the SimPET-X system. There was no notable interference between SimPET-X and M7 MRI. SimPET-X provided high-quality mouse images with superior spatial resolution, sensitivity, and counting rate performance.

conclusionSimPET-X yielded a remarkably improved sensitivity and NECR compared with SimPET

Indexed as

Phantoms, ImagingAnimalsEquipment DesignMagnetic Resonance ImagingMiceMolecular ImagingPositron-Emission TomographySensitivity and SpecificityWhole Body ImagingAnimal PETInstrumentationMolecular imagingPET/MRI

Identifiers

PMID33768465
OpenAlexW3138015405

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.