Evidence map›Paper›PMID 33763642›Full record

ArticleJournal of structural biology: X2021

Optimization of negative stage bias potential for faster imaging in large-scale electron microscopy.

Ryan Lane, Yoram Vos, Anouk H G Wolters, Luc van Kessel, S Elisa Chen, Nalan Liv, Judith Klumperman, Ben N G Giepmans, Jacob P Hoogenboom

Abstract read
In one paragraph

Article in Journal of structural biology: X, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ryan LaneImaging Physics, Delft University of Technology, The Netherlands.
Yoram VosImaging Physics, Delft University of Technology, The Netherlands.
Anouk H G WoltersDepartment of Biomedical Sciences of Cells and Systems, University Groningen, University Medical Center Groningen, The Netherlands.
Luc van KesselImaging Physics, Delft University of Technology, The Netherlands.
S Elisa ChenCell Biology, Center for Molecular Medicine, University Medical Center Utrecht, The Netherlands.
Nalan LivCell Biology, Center for Molecular Medicine, University Medical Center Utrecht, The Netherlands.
Judith KlumpermanCell Biology, Center for Molecular Medicine, University Medical Center Utrecht, The Netherlands.
Ben N G GiepmansDepartment of Biomedical Sciences of Cells and Systems, University Groningen, University Medical Center Groningen, The Netherlands.
Jacob P HoogenboomImaging Physics, Delft University of Technology, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Large-scale electron microscopy (EM) allows analysis of both tissues and macromolecules in a semi-automated manner, but acquisition rate forms a bottleneck. We reasoned that a negative bias potential may be used to enhance signal collection, allowing shorter dwell times and thus increasing imaging speed. Negative bias potential has previously been used to tune penetration depth in block-face imaging. However, optimization of negative bias potential for application in thin section imaging will be needed prior to routine use and application in large-scale EM. Here, we present negative bias potential optimized through a combination of simulations and empirical measurements. We find that the use of a negative bias potential generally results in improvement of image quality and signal-to-noise ratio (SNR). The extent of these improvements depends on the presence and strength of a magnetic immersion field. Maintaining other imaging conditions and aiming for the same image quality and SNR, the use of a negative stage bias can allow for a 20-fold decrease in dwell time, thus reducing the time for a week long acquisition to less than 8 h. We further show that negative bias potential can be applied in an integrated correlative light electron microscopy (CLEM) application, allowing fast acquisition of a high precision overlaid LM-EM dataset. Application of negative stage bias potential will thus help to solve the current bottleneck of image acquisition of large fields of view at high resolution in large-scale microscopy.

Indexed as

Correlative light and electron microscopyElectron microscopyHigh-throughput imagingLarge-scale electron microscopyStage biasVolume electron microscopy

Identifiers

PMID33763642
PMCPMC7973379

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.