ArticleJournal of the mechanical behavior of biomedical materials2021
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.
Article in Journal of the mechanical behavior of biomedical materials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Advanced porous hip implants: A comprehensive review.Heliyon · 2024Review
- Fretting-Corrosion Apparatus with Low Magnitude Micro-motion (≤ 5 μm) for Hip Implant Taper Junctions: Development and Preliminary Outcome.Journal of bio- and tribo-corrosion · 2024Article
- Early Detection of Fretting Corrosion in Hip Replacement by Acoustic Emission Non-Invasive Technique.Thin solid films · 2024Article
- Corrosion Behavior of Selective Laser Melting (SLM) Manufactured Ti6Al4V Alloy in Saline and BCS Solution.Journal of bio- and tribo-corrosion · 2022Article
- In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Contemporary hip implants feature a modular design. Increased reported failure rates associated with the utilization of modular junctions have raised many clinical concerns. Typically, these modular interfaces contain circumferential machining marks (threads or microgrooves), but the effect of the machining marks on the fretting-corrosion behavior of total hip implant materials is unknown. This study reports the effects of microgrooves on the fretting-corrosion behavior of hip implant materials. The flat portions of two cylindrical, polished, CrCrMo alloy pins were loaded horizontally against one rectangular Ti alloy rod. Two surface preparation groups were used for the Ti6Al4V rod (polished and machined). The polished group was prepared using the same methods as the CoCrMo pins. The machined samples were prepared by creating parallel lines on the rod surfaces to represent microgrooves present on the stem tapers of head-neck modular junctions. Newborn calf serum (30 g/L protein content; 37 °C) at pH of levels of 7.6 and 3.0 were used to simulate the normal joint fluid and a lowered pH within a crevice, respectively. The samples were tested in a fretting corrosion apparatus under a 200N normal force and a 1Hz sinusoidal fretting motion with a displacement amplitude of 25 μm. All electrochemical measurements were performed with a potentiostat in a three-electrode configuration. The results show significant differences between machined samples and polished samples in both electrochemical and mechanical responses. In all cases, the magnitude of the drop in potential was greater in the machined group compared to the polished group. The machined group showed a lower total dissipated friction energy for the entire test compared to the polished group. Additionally, the potentiostatic test measurements revealed a higher evolved charge in the machined group compared to the polished group at both pH conditions (pH 7.6 and 3.0). The machined surfaces lowered the overall dissipated friction energy at pH 7.6 compared to pH 3.0, but also compromised electrochemical performance in the tested conditions. Therefore, the role of synergistic interaction of wear and corrosion with surface topographical changes is evident from the outcome of the study. Despite the shift towards higher electrochemical destabilization in the machined group, both polished and machined groups still exhibited a mechanically dominated degradation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.