Evidence map›Paper›PMID 33748604›Full record

ArticleACS omega2021

Design and Fabrication of a Customized Partial Hip Prosthesis Employing CT-Scan Data and Lattice Porous Structures.

Jorge Corona-Castuera, Daniela Rodriguez-Delgado, John Henao, Juan Carlos Castro-Sandoval, Carlos A Poblano-Salas

Abstract read
In one paragraph

Article in ACS omega, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jorge Corona-CastueraCIATEQ A.C., Av. Manantiales 23-A, Parque Industrial Bernardo Quintana, El Marqués, Querétaro 76246, Mexico.
Daniela Rodriguez-DelgadoCIATEQ A.C., Av. Manantiales 23-A, Parque Industrial Bernardo Quintana, El Marqués, Querétaro 76246, Mexico.
John HenaoCONACyT-CIATEQ A.C., Av. Manantiales 23-A, Parque Industrial Bernardo Quintana, El Marqués, Querétaro 76246, Mexico.
Juan Carlos Castro-SandovalCIATEQ A.C., Av. Manantiales 23-A, Parque Industrial Bernardo Quintana, El Marqués, Querétaro 76246, Mexico.
Carlos A Poblano-SalasCIATEQ A.C., Av. Manantiales 23-A, Parque Industrial Bernardo Quintana, El Marqués, Querétaro 76246, Mexico.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As a larger elderly human population is expected worldwide in the next 30 years, the occurrence of aging-associated illnesses will also be increased. The use of prosthetic devices by this population is currently important and will be even more dramatic in the near future. Hence, the design of prosthetic devices able to reduce some of the problems associated with the use of current components, such as stress shielding, reduced mobility, infection, discomfort, etc., becomes relevant. The use of additive manufacturing (AM) and the design fabrication of self-supported cellular structures in the biomedical area have opened up important opportunities for controlling the physical and mechanical properties of hip implants, resulting in specific benefits for the patients. Different studies have reported the development of hip prosthetic designs employing AM, although there are still opportunities for improvement when it comes to customized design and tuning of the physical and mechanical properties of such implants. This work shows the design and manufacture by AM of a personalized stainless-steel partial hip implant using tomography data and self-supported triply periodic minimal surface (TPMS) cell structures; the design considers dimensional criteria established by international standards. By employing tomography data, the external dimensions of the implant were established and the bone density of a specific patient was calculated; the density and mechanical properties in compression of the implant were modulated by employing an internal gyroid-type cell structure. Using such a cell structure, the patient's bone density was emulated; also, the mechanical properties of the implant were fine-tuned in order to make them comparable to those reported for the bone tissue replaced by the prosthesis. The implant design and manufacturing methodology developed in this work considered the clinical condition of a specific patient and can be reproduced and adjusted for different types of bone tissue qualities for specific clinical requirements.

Identifiers

PMID33748604
PMCPMC7970571

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.